RESIDENTIAL DESIGN GUIDE

Rakewall w/ Counter & Receiver

Detail for Installation of Siding Prior to Panels

Description

Installation Information

1

Residential Counter

Flashing Receiver

Install bottom edge of flashing 5-1/2" up

from the substrate.

2

Fastener

by Others

Fasten as shown

3

Pop

Rivet

Fasten Receiver to the Counter Flashing

12" o.c.

4

Residential Counter

Flashing Flat

Slide into open hem of Counter Flashing

Receiver

5

Residential

Rakewall

Slide Residential Rakewall over the

Image II panel edge.

6

Tube

Sealant

Apply a continuous bead of

Tube Sealant to the slip pocket.

7

Tube

Sealant

Apply a continuous bead of

Tube Sealant to the inside corner of the

panel prior to attaching the flashing.

Push flashing down over the panel

turn-up and into the sealant.

Wipe away excess sealant with finger or

plastic caulk smoothing tool.

8

Vertical Seam

Panel

Turn up panel 1-3/8" for Rakewall Slip

Pocket

5-1/2"