Uv w y, Xz v u z, Image ii hip end cap detail – Metal Sales Residential User Manual
Page 40

© Metal Sales Manufacturing Corporation / Subject to change without notice 3/14
39
RESIDENTIAL PRODUCT GUIDE
Image II Hip End Cap Detail
u
v
w
y
Description
Installation Information
1
Ridge/Hip
Cover
Open hems of the Hip Flashing slide onto 1" top flanges of Z-Closure. Fold 1" hems over top
flashings of Vertical Seam end cap. Attach high side of flashing as shown on page 38.
2
Image II
Z-Closure
Z-Closures over continuous Double Bead Tape Sealant.
3
Pancake Head
Wood Screw
Attach Image II Z-Closures with Pancake Head Wood Screws or Truss Head Wood Screws.
4
Double Bead
Tape Sealant
Double Bead Tape Sealant required under Z-Closures and over panel ribs. A weep hole/gap in
the Double Bead Tape Sealant is required at the low side of the Z-Closure, along the panel rib.
5
Image II
Panel
Turn the Image II panel ends turned up to vertical 1" at the hip.
6
Image II
End Cap
Lower flange of End Cap covers the panel hem.
7
Pop Rivet
2 Pop Rivets per miter, attaching End Caps to the Z-Closures.
A
A
x
z
v
u
z
{
{
1/2"-1" miter, depending on slope