Vertical seam design information, Residential design guide, General information – Metal Sales Residential User Manual
Page 6

© Metal Sales Manufacturing Corporation / Subject to change without notice 6/14
5
RESIDENTIAL DESIGN GUIDE
1. Theoretical section properties have been calculated per AISI 2007 'North American Specification for the Design of Cold-
Formed Steel Structural Members'. Ixx and Sxx are effective section properties for deflection and bending.
2. Allowable loads are calculated in accordance with AISI 2007 specifications considering bending, shear, combined bending
and shear, deflection and ASTM E 1592 uplift testing for 24 ga and 22 ga and UL 580 uplift testing for 26 ga. Allowable
loads consider the 3 or more equal spans condition. Allowable loads do not address web crippling, fasteners or support
material. Panel weight is not considered.
3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.
4. Allowable loads do not include a 1/3 stress increase for wind.
SECTION PROPERTIES
ALLOWABLE UNIFORM LOADS, psf
For various fastener spacings
Ga. Width
in
Yield
ksi
Weight
psf
Top In Compression Bottom In Compression
Inward
Load
Outward
Load
Ixx
in
4
/ft
Sxx
in
3
/ft
Ixx
in
4
/ft
Sxx
in
3
/ft
2.5' 3' 3.5' 4' 4.5' 5' 2.5' 3' 3.5' 4' 4.5' 5'
26
12
50
1.06
0.0781
0.0530
0.0377
0.0408
148 104 77 59
-
-
55 49 42 36
-
-
26
16
50
0.97
0.0614
0.0402
0.0283
0.0306
114 79 58 45
-
-
114 79 58 45
-
-
26
18
50
0.94
0.0553
0.0358
0.0253
0.0273
-
-
-
-
-
-
-
-
-
-
-
-
24
12
50
1.38
0.1118
0.0774
0.0533
0.0557
204 143 105 81 64 52
44 43 42 41 40 39
24
16
50
1.26
0.0885
0.0589
0.0398
0.0419
153 107 79 61 48 39
42 38 34 30 27 24
24
18
50
1.22
0.0800
0.0526
0.0353
0.0372
136 95 70 54 43 35
33 30 27 24 20 19
ATTACHMENT DETAIL
PANEL CLIPS
Clip
Vertical Seam Panel
Slope
Clips
Coverage
Lengths
Fasteners
Availability
GENERAL INFORMATION
The minimum recommended slope for the Vertical Seam
roof panel is 3:12 over open framing and 1:12 over solid
substrate.
Clip spacing is based upon the spacing of structural
framing members and loading requirements.
Vertical Seam panels are available in a 1
3
/
4
" seam height
with a 12", 16", or 18" width coverage.
Minimum factory cut length is 5'-0". Maximum
recommended panel length is 45'-0". Longer panels
require additional consideration in packaging,
shipping, and erection. Please consult Metal Sales for
recommendations.
The fastener selection guide should be consulted for
choosing the proper fastener for specific applications.
Quantity and type of fastener must meet necessary
loading and code requirements.
NOTE: All panels are subject to surface distortion due to
improperly applied fasteners. Overdriven fasteners will
cause stress and induce oil canning across the face of
the panel at or near the point of attachment.
Finishes: in PVDF (Kynar 500
®
), MS Colorfast45
®
, and
Acrylic Coated Galvalume
®
.
Gauges: 24 gauge or 26 gauge
Pancake Head
Fastener
Factory Applied Sealant
Base
Vertical
Tab
UL90 Clip - 2 Fasteners
Vertical Seam Design Information