5

RESIDENTIAL DESIGN GUIDE

1. Theoretical section properties have been calculated per AISI 2007 'North American Specification for the Design of Cold-

Formed Steel Structural Members'. Ixx and Sxx are effective section properties for deflection and bending.

2. Allowable loads are calculated in accordance with AISI 2007 specifications considering bending, shear, combined bending

and shear, deflection and ASTM E 1592 uplift testing for 24 ga and 22 ga and UL 580 uplift testing for 26 ga. Allowable

loads consider the 3 or more equal spans condition. Allowable loads do not address web crippling, fasteners or support

material. Panel weight is not considered.

3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.

4. Allowable loads do not include a 1/3 stress increase for wind.

SECTION PROPERTIES

ALLOWABLE UNIFORM LOADS, psf

For various fastener spacings

Ga. Width

in

Yield

ksi

Weight

psf

Top In Compression Bottom In Compression

Inward

Load

Outward

Load

Ixx

in

4

/ft

Sxx

in

3

/ft

Ixx

in

4

/ft

Sxx

in

3

/ft

2.5' 3' 3.5' 4' 4.5' 5' 2.5' 3' 3.5' 4' 4.5' 5'

26

12

50

1.06

0.0781

0.0530

0.0377

0.0408

148 104 77 59

-

-

55 49 42 36

-

-

26

16

50

0.97

0.0614

0.0402

0.0283

0.0306

114 79 58 45

-

-

114 79 58 45

-

-

26

18

50

0.94

0.0553

0.0358

0.0253

0.0273

-

-

-

-

-

-

-

-

-

-

-

-

24

12

50

1.38

0.1118

0.0774

0.0533

0.0557

204 143 105 81 64 52

44 43 42 41 40 39

24

16

50

1.26

0.0885

0.0589

0.0398

0.0419

153 107 79 61 48 39

42 38 34 30 27 24

24

18

50

1.22

0.0800

0.0526

0.0353

0.0372

136 95 70 54 43 35

33 30 27 24 20 19

ATTACHMENT DETAIL

PANEL CLIPS

Clip

Vertical Seam Panel

Slope

Clips

Coverage

Lengths

Fasteners

Availability

GENERAL INFORMATION

The minimum recommended slope for the Vertical Seam

roof panel is 3:12 over open framing and 1:12 over solid

substrate.

Clip spacing is based upon the spacing of structural

framing members and loading requirements.

Vertical Seam panels are available in a 1

3

/

4

" seam height

with a 12", 16", or 18" width coverage.

Minimum factory cut length is 5'-0". Maximum

recommended panel length is 45'-0". Longer panels

require additional consideration in packaging,

shipping, and erection. Please consult Metal Sales for

recommendations.

The fastener selection guide should be consulted for

choosing the proper fastener for specific applications.

Quantity and type of fastener must meet necessary

loading and code requirements.

NOTE: All panels are subject to surface distortion due to

improperly applied fasteners. Overdriven fasteners will

cause stress and induce oil canning across the face of

the panel at or near the point of attachment.

Finishes: in PVDF (Kynar 500

®

), MS Colorfast45

®

, and

Acrylic Coated Galvalume

®

.

Gauges: 24 gauge or 26 gauge

Pancake Head

Fastener

Factory Applied Sealant

Base

Vertical

Tab

UL90 Clip - 2 Fasteners

Vertical Seam Design Information