16

Component Identification

9

Reservoir

Holds the hydraulic fluid and houses the hydraulic pump and motor.

The surge suppressor (optional) is mounted to the pump.

10

Hydraulic and Water
Connections

Connection points for the hydraulic fluid distribution system, water
source, and return lines.

11

Water Flow Regulator

Sets the amount of water flowing through the heat exchanger. Adjust

the water flow to regulate the temperature of the hydraulic fluid.

12

Drain Valve

Drains the hydraulic fluid from the reservoir.

13

High Pressure Filter
Location

The high pressure filter is optional. If provided, it would be located

where indicated in the figure.

14

Output Pressure Control

Sets the output pressure of the HPU.

15

Heat Exchanger

Cools the hydraulic fluid by using an oil-to-water heat exchanger. The

heat exchanger removes most of the heat generated by the HPU.

16

Temperature Gage

Displays the temperature of the hydraulic fluid.

17

Return Filter

Filters particles out of the hydraulic fluid as it is returned to the HPU.

18

Power Disconnect Switch

Disconnects the incoming power from the HPU. The switch is a
lockable, mechanical latch. Power is removed whenever the door to

the electrical enclosure is open (the switch is in the off position).

However, incoming power lines to the switch are live unless power is
removed externally. The power disconnect switch is located on the

front panel of the electrical enclosure (item 5).

19

Hazard placards

Hazard placards contain specific safety information and are affixed
directly to the system so they are plainly visible. Each placard
describes a product-related hazard. When possible, international
symbols (icons) are used to graphically indicate the type of hazard and
the placard label indicates its severity. The hazard placards are located
on the front panel of the electrical enclosure (item 5).

20

User Interface Panel

Controls the operation of the HPU and indicates the current status of

several detectors. Also used for HPU setup. The user interface panel
is located on the front panel of the electrical enclosure (item 5).

21

Nameplate

Provides basic product information such as model number, serial

number, and electrical information. The nameplate is located on the
electrical enclosure (item 5).

Component Descriptions (part 2 of 2)

Item Component

Description

Advertising