Sample the hydraulic fluid, Sample the hydraulic fluid 59 – MTS Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2-11 User Manual

Page 59

Advertising
background image

Sample the Hydraulic Fluid

Model 505G2.07/.11 SilentFlo™ HPU

59

Sample the Hydraulic Fluid

This section describes how to check the quality of the hydraulic fluid. Review the
following hints before obtaining your sample:

Avoid contamination.

Keep the sample bottle in the storage box of the hydraulic fluid
sampling kit until it is needed.

Do not remove the cap from the bottle until immediately before taking
the sample.

Do not set the cap down on a dirty surface or in an area where airborne
dust can settle.

For additional information on hydraulic fluid care, see the Hydraulic Fluid
Care Guide
(part number 050-000-536) found in the documentation package
inside the electrical control box.

Hold the hose valve assembly still when taking a sample.

Do not let the hose sample assembly line touch the mouth of the bottle or go
into the bottle.

Prerequisite

You will need a hydraulic fluid sampling kit (part number 055-589-601).

Procedure

Take a fluid sample from the reservoir to get a visual indication of the fluid level
and relative contamination. Clean hydraulic fluid is clear and has an amber color.
If the composition of the fluid appears to have changed, obtain a sample of the
hydraulic fluid from the sample port and check the fluid qualities.

Control Manifold

Bypass Valve

Hose Valve Assembly

Needle Valve

Sample Port