MTS Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2-11 User Manual

Page 67

Advertising
background image

Precharging the Surge Suppressor Accumulator

Model 505G2.07/.11 SilentFlo™ HPU

67

Determining a

pressure check

interval

The precharge pressure checking intervals of your surge suppressor depends on
how your system is used. Vigorous use causes more rapid pressure loss and thus
requires checking and recharging more often.

Initially, check the surge suppressor precharge pressure every month or 160
operating hours. If the precharge pressure changes more than 200 psi during this
time period, recharge the surge suppressor and check the pressure twice as often
in the future. If the precharge pressure changes less than 200 psi, check the
pressure half as often.

When you have established a regular interval for checking the precharge
pressure, note the amount of pressure loss that occurs each time the pressure is
checked. An increase in pressure loss during the period between checks may
indicate that the surge suppressor seals or bladder require replacement.

Checking precharge

pressure

The nitrogen precharge should be about 50–60% of the output pressure. Monitor
the pressure gage. If the pressure reading is outside the range of 10.3–12.5 MPa
(1500–1800 psi), perform the procedure “Changing the precharge pressure.”

Charging Kit

Changing the

precharge pressure

The nitrogen precharge should be within the range of 10.3–12.5 MPa (1500–
1800 psi) which is 50–60% of the output pressure (21 MPa or 3000 psi). Perform
one of the following procedures to change the precharge pressure.

Decreasing pressure

To decrease the precharge pressure:

Low Pressure Gage

High Pressure Gage
0–21 MPa (0–3000 psi)

Gage Protector
(factory set to
limit pressure to
the gage to

Extensi

Bleed

Input
Check

Nitrogen
Supply Hose

Regulator
Output
Pressure

Nitrogen
Bottle
Pressure

Core-Type Valve
To Open and
Close Use Chuck

Nitrogen
Bottle

Nitrogen
Bottle

Regulator

Regulator
Shut-Off

You must supply these

Check

Lockn

Valve Stem

Open

Clos

Poppet-Type Valve
To Open and Close
Use Chuck Valve

Clos

Valve

Valve

Open

Ope

Clos

Advertising