MTS Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2-11 User Manual

Page 33

Advertising
background image

HPU Setup

Model 505G2.07/.11 SilentFlo™ HPU

33

Mean Temp/numeric display and
Deadband/numeric display

Part of the Analog Option;only displayed
if the Analog Option was purchased.

Mean Temp (deg) - blue-green: Indicator used as a label for the
pushbutton switch below it.

Deadband (deg) - blue-green: Indicator used as a label for the
pushbutton switch below it.

Mean Level numeric display - pushbutton/indicator - gray: Used
to set the mean level operating temperature of the hydraulic fluid.

Push the button to display a numeric keypad. With the keypad

displayed, use the number keys to set the desired mean level then
press Enter to set the value and return to the status screen. Once

value has been set on the keypad, that value is displayed.

Deadband numeric display - pushbutton/indicator - gray: Used to

set the allowable deviation from the mean level operating

temperature of the hydraulic fluid. Push the button to display the
numeric keypad. With the keypad displayed, use the number keys

to set the desired deadband level then press Enter to set the value

and return to the status screen. Once value has been set on the
keypad, that value is displayed.

Pressure Filter Not Present/Pressure
Filter Present

Pushbutton /Indicator. This button is used to define if a pressure

filter is present.

Pressure Filter Not Present- gray: The HPU does not have a

pressure filter.

Pressure Filter Present- black: The HPU does have a pressure

filter.

Temp Display In (deg)

Part of the Analog Option;only displayed
if the Analog Option was purchased.

Pushbutton/Indicator: Used to select temperature display in either

Celsius or Fahrenheit. Push to alternate between the two

temperature scales.

Temp Display in

°

F - gray.

Temp Display in

°

C - black.

Pressure Display In (units)

Part of the Analog Option;only displayed
if the Analog Option was purchased.

Pushbutton/Indicator: Used to select the units for pressure displays

in either psi or MPa. Push to alternate between the two pressure
units.

Pressure Display in psi - gray.

Pressure Display in MPa - black.

Screen select buttons

The Main, Status, and Setup pushbuttons/indicators are described
in the Main Screen section; refer to

“Main Screen”

on page 36.

The HMI Setup pushbutton/indicator is for MTS service personnel
and used to display a screen that is used to define factory settings

such as serial number and HMI software version.

Name and Location

Description

Advertising