22

Introduction

For the most accurate high frequency test results, use a load unit with a fatigue
rating that is larger than its actuator’s force rating.

For example, a Model 318.25 Load Unit with a 55 kip fatigue rating and a 22 kip
actuator will have smaller deflections than a Model 318.10 Load Unit with a 22
kip fatigue rating and a 22 kip actuator.

Spring rates are determined at each load unit’s full fatigue rating with its
crosshead raised 1270 mm (50 in.) above the baseplate.

The Stiffness Graph shows how stiffness is affected when the height of the
crosshead is changed.

A

B

D

C

D

EFLECTIONS

M

ODEL

318.10

100

K

N/22

KIP

M

ODEL

318.25

250

K

N/55

KIP

M

ODEL

318.50

500

K

N/110

KIP

A - B base

0.15 mm

0.006 in

0.18 mm

0.007 in

0.20 mm

0.008 in

B - C columns

0.10 mm

0.004 in

0.15 mm

0.006 in

0.18 mm

0.007 in

C - D crosshead

0.13 mm

0.005 in

0.25 mm

0.010 in

0.28 mm

0.011 in