ga6HR/6HRS 60 hz gENERATOR • OpERATiON ANd pARTs mANuAl — REv. #0 (08/12/14) — pAgE 19

COmPONENTS (GENERATOR)

QUARTZ

0N

OFF

OPERATION

SWITCH

ON

OFF

GA-6HR

MANUAL RESET

P
O
W
E
R

F
A
U
L
T

120

V

120

AC VOLTMETER

120V

30A

120/240V

30A

120V

20A

AC CIRCUIT BREAKER

GFCI PROTECTED

120V

240/120V

FULL POWER

SWITCH

20A

120V

20A

120V

QUARTZ

0N

OFF

OPERATION

SWITCH

ON

OFF

GA-6HR

MANUAL RESET

P
O
W
E
R

F
A
U
L
T

120

V

120

AC VOLTMETER

120V

30A

120/240V

30A

120V

20A

AC CIRCUIT BREAKER

GFCI PROTECTED

120V

240/120V

FULL POWER

SWITCH

20A

120V

20A

120V

QUARTZ

0N

OFF

IDLE

CONTROL

GA-6HRS

MANUAL RESET

P
O
W
E
R

F
A
U
L
T

120

V

120

AC VOLTMETER

120V

30A

120/240V

30A

120V

20A

AC CIRCUIT BREAKER

GFCI PROTECTED

120V

240/120V

FULL POWER

SWITCH

20A

120V

20A

120V

START

SWITCH

OPERATION

SWITCH

IDLE

CONTROL

IDLE

CONTROL

1

2

4

3

5

6

7

8

8

11

12

13

14

15

9

10

Figure 4. Generator Components

1.

gFCi duplex Receptacles – NEMA 5-20R, GFCI

receptacle will provide 120V@ 20 amps.

2.

hour meter – Indicates the number hours the generator

has been in use.

3.

lifting Ball Eye – Attach a rope or chain to this lifting

eye when lifting of the generator is required. Never

stand underneath the generator while it is being lifted.

Place lifting eye in down position when not in use.

4.

gFCi sensing module – Interrupts power when a

ground fault exist.

5.

main Breaker – This 2-pole, 23 amp circuit breaker

protects the generator from short circuiting or

overloading. When starting the generator always have

the circuit breaker placed in the "

OFF" position.

6.

AC-voltmeter – This voltmeter indicates (with a

mark) the rated 60 Hz (single-phase) output voltage.

In addition the voltmeter can also be used as a

diagnostic tool. If the voltmeter indicator (needle) is

below the rated voltage, engine problems may exist

(low/high RPM's). To prevent damage to the generator

or power tools turn the generator

OFF and consult your

authorized Multiquip service dealer.

7.

idle Control switch – The generator is provided with

an automatic idle control device for noise suppression

and reduced fuel consumption.
The automatic idle control automatically engages under

a no-load condition. With the automatic idle control

switched “

ON”, the engine revolutions will automatically

drop to about 2600 rpm (low-speed operation) within

3 seconds after the load stops. When the operation is

resumed, the engine speed is automatically increased

to about 3600 rpm (high-speed operation) as soon as

the load is connected.

8.

Operation switch – Place switch in the "ON" position

(up) for normal operation. To turn-off the generator,

place the operation switch in the "OFF" position (down)

9.

start switch – Press this pushbutton switch to start

the generator (GA6HRS only).

10.

120/240v Output Receptacle – NEMA L14-30R twist-

lock receptacle will provide 240V, 60 Hz @ 20.8 amps,

or 120V@ 41.6 amps (X2) 60 Hz. Depending on the

position of the full power switch.

11.

120v Output Receptacle – NEMA L5-30R twist-lock

receptacle will provide 120V, 30 amps, 60 Hz.

12.

120v Output Receptacle – NEMA L5-20R twist-lock

receptacle will provide 120V, 20 amps, 60 Hz.

13.

Battery – This unit is equipped with a 12 VDC

battery. Replace with only recommended type battery

(GA6HRS only).

14.

Charcoal Canister – A container filled with activated

charcoal that traps gasoline vapors emitted by the

fuel

system.

15.

ground – This ground connection point should be

connect to a good earth ground (ground rod).