Maintenance – Multiquip GA-6HRS User Manual

Page 30

Advertising
background image

pAgE 30 — ga6HR/ga6HRS 60 hz gENERATOR• OpERATiON ANd pARTs mANuAl — REv. #0 (08/12/14)

mAINTENANCE

mAiNTENANCE

Perform the scheduled maintenance procedures as defined

by Table 6 on the previous page:

daily

Thoroughly remove dirt and oil from the engine and

control area. Clean or replace the air cleaner elements as

necessary. Check and retighten all fasteners as necessary.

Wiring

Inspect the entire generator for bad or worn electrical wiring

or connections. If any wiring or connections are exposed

(insulation missing) replace wiring immediately.

piping and hose Connection

Inspect all piping, oil hose, and fuel hose connections for

wear and tightness. Tighten all hose clamps and check fuel

or leaks. If any hose (fuel or oil) lines are defective replace

them immediately.

Fuel strainer

1. Thoroughly clean the area around the fuel cap.
2. Remove the fuel cap from the fuel tank.
3. Next, remove, inspect and clean the fuel strainer

(Figure 31) with solvent.

Figure 31. Fuel Strainer

spark plug

1. Remove and clean the spark plug (Figure 32), then

adjust the spark gap to 0.024 ~0.028 inch (0.6~0.7

mm). This unit has electronic ignition, which requires

no adjustments.

Figure 32. Spark Plug Gap

ENgiNE Oil

2. Drain the engine oil when the oil is warm as shown in

Figure 33.

3. Remove the oil drain bolt and sealing washer and allow

the oil to drain into a suitable container.

4. Replace engine oil with recommended type oil as listed

in Table 4. For engine oil capacity, see Table 2 (engine

specifications).

dO NOT overfill.

5. Install drain bolt with sealing washer and tighten

securely.

Figure 33. Draining Engine Oil

Advertising