ga6HR/6HRS 60 hz gENERATOR • OpERATiON ANd pARTs mANuAl — REv. #0 (08/12/14) — pAgE 29

mAINTENANCE

Use Table 6 as a general maintenance guideline when

servicing your engine. For more detail engine maintenance

information, refer to the engine owner's manual supplied

with your engine.

Table 6. Engine maintenance schedule

dEsCRipTiON (3)

OpERATiON

BEFORE

FiRsT

mONTh OR

10 hRs.

EvERY 3

mONThs

OR 25 hRs.

EvERY 6

mONThs

OR 50 hRs.

EvERY

YEAR OR

100 hRs.

EvERY

2 YEARs OR

200 hRs.

Engine Oil

CHECK

X

CHANGE

X

X

X

X

Air Cleaner

CHECK

X

X

CHANGE

X (1)

Charcoal Canister (4)

REPLACE

All Nuts & Bolts

RETIGHTEN IF

NECESSARY

X

Spark Plug

CHANGE

X

REPLACE

X

Cooling Fins

CHECK

X

Spark Arrester

CLEAN

X

Fuel Tank

CLEAN

X

Fuel Strainer

CHECK

X

X

Idle Speed

CHECK-ADJUST

X (2)

Valve Clearance

CHECK-ADJUST

X

X

X (2)

Fuel lines

CHECK

Every 2 years, replace if necessary (2)

(1) Service more frequently when used in

dusTY

areas.

(2) These items should be serviced by your service dealer, unless you have the proper tools and are mechanically

proficient. Refer to the HONDA Shop Manual for service procedures.
(3) For commercial use, log hours of operation to determine proper maintenance intervals.

(4) Charcoal canister is maintenance free (non-servicable). Replace only if damaged.