Creepage and clearance distances, cti, How to identify the maximum voltage – Northern Connectors Harting DIN 41 612 Connectors User Manual

Page 11

Advertising
background image

00

.

05

60

63

32

63

110

120

125

80

125

127

150

2)

160 – 160

208

200 125 200

220

230

250 160 250

240

300

2)

320 – 320

380

400

400 250 400

415

440

500 250 500

480

500 320 500

500
575

630 400 630

600

2)

630 – 630

660

630 400 630

690
720

800 500 800

830
960

1000 630 1000

1000

2)

1000 –

1000

Gen

er

al

in

fo

rma

tio

n

Creepage and clearance distances, CTI

50

0.33

0.50

0.80

1.5

100

0.50 0.80 1.5 2.5

150

0.80

1.5 2.5 4.0

300

1.5 2.5 4.0 6.0

600

2.5 4.0 6.0 8.0

1000 4.0 6.0 8.0 12.0

Table 00.01

Voltages phase-to-earth

derived from rated system voltages

up to U

r.m.s.

and U

I

II

III

IV

Rated impulse withstand voltages in kV for installation category

(Voltage form: 1.2/50 µs according to DIN IEC 60060-1)

Table 00.02

Minimum clearances in mm up to 2000 m above sea level

1)

Pollution degree

Pollution degree

Case A

Case B

(Inhomogeneous field

3)

)

(Homogeneous field

2)

)

1 2 1 2

Rated impulse

withstand

voltage in kV

0.33

0.01 0.01

0.50

0.04 0.2 0.04 0.2

0.80

0.1 0.1

1.5 0.5 0.5 0.3 0.3

2.5 1.5 1.5 0.6 0.6

4.0 3

3 1.2 1.2

6.0 5.5 5.5 2

2

8.0 8

8 3

3

1)

For higher altitudes see table 2b from DIN VDE 0110 for multiplying factors.

2)

Verification by an impulse voltage test is required if the clearance is less than the value specified for case A.

3)

Point to plane.

Table 00.03 a.

Single phase, three or two wire AC

or DC systems

Table 00.03 b.

Three phase, four or three wire

AC systems

Rated voltage in V

Nominal

voltage

of supply

system

1)

U

r.m.s.

or U

in V

Phase-to-

phase

All systems

(between

conduc tors of

different polarity

for U

)

U

r.m.s.

or U

Rated voltage in V

Nominal

voltage

of supply

system

1)

U

r.m.s.

in V

Phase-

to-

phase

All

systems

U

r.m.s.

Phase-to-earth

Phase-to-

earth

U

r.m.s.

or U

U

r.m.s.

U

r.m.s.

12.5

12.5

24

25 –

25

30

32 –

42

48

50 –

50

2)

60

63 –

60/30

63

32

100

2)

100 –

110 125 –

120
150

2)

160 –

220 250 –
220/110 250 125

240/120
300

2)

320 –

440/220 500 250
600

2)

630 –

480/960 1000 500
1000

2)

1000 –

1)

This voltage can be the same as the rated voltage of the equipment.

2)

These values correspond to the values of table 00.01.

In countries where both star and delta, earthed and unearthed supply systems are used the values for delta

systems only should by used. Systems earthed across impedances are treated as unearthed systems.

Table 00.04

Rated voltage (V)

U~

r.m.s.

or U_

12.5

25

32

50

63

80

100

125

160

200

250

320

400

500

630

800

1000

Minimum creepage distance (mm)

Degree of pollution 1:

CTI group II + III a/b

0.09 0.125 0.14

0.18

0.2

0.22

0.25

0.28

0.32

0.42

0.56

0.75

1

1.3

1.8

2.4

3.2

Degree of pollution 2:

CTI group III a/b

0.42 0.5

0.53

1.2

1.25

1.3

1.4

1.5

1.6

2

2.5

3.2

4

5

6.3

8

10

CTI group II

0.42 0.5

0.53

0.85

0.9

0.95

1

1.05

1.1

1.4

1.8

2.2

2.8

3.5

4.5

5.6

7.1

Exemplary calculation

What voltage can be used, if the creepage, the installation category

and the degree of pollution are known:

Creepage

1.2 mm

3.0 mm

8.0 mm

Installation

category

II

II

II

Degree of polution

2

2

2

CTI-Value

< 400 > 400 < 400 > 400 < 400

> 400

Isolation group

III a/b

II

III a/b

II

III a/b

II

Rated voltage

50 V

160 V 250V 400 V 800 V 1,000 V

Nominal voltage

of supply system

50 V

150 V 220 V 380 V 720 V 1,000 V

How to identify the maximum voltage

1. Define the installation category
2. Define the degree of pollution expected
3. Select the rated impulse withstand voltage in kV from table 00.02
4. Select the voltage phase to earth derived from rated system voltages

from table 00.01

5. Select the rated voltage from table 00.04
6. Define the number of phases and whether table 00.03 a

or table 00.03 b is relevant for the application

7. Select the nominal voltage of supply system from table 00.03 a

or 00.03 b

8. Select the lower voltage from point 4 and 7