Technical characteristics types d and e – Northern Connectors Harting DIN 41 612 Connectors User Manual

Page 110

Advertising
background image

03

.

10

DIN

P

ow

er

up t

o 6 A

Technical characteristics

Types D and E

Current carrying capacity

The current carrying capacity is limited by maximum temperature of

materials for inserts and contacts including terminals . The current

capacity curve is valid for continuous, non interrupted current loaded

contacts of connectors when simultaneous power on all contacts is

given, without exceeding the maximum temperature .

Control and test procedures according to DIN IEC 60 512

Fitting the crimp contacts

After crimping the wires onto the contacts with the help of a crimp-

ing tool or an automatic crimping machine the contacts should be

correctly oriented and inserted into the cavities of the connector

moulding in the required configuration . They snap into position and

are firmly held in place . A light pull on the wire assures the correct

tensile strength of the contact . When using stranded wires with a

gauge below 0 .37 mm² an insertion tool is necessary .

Removing the crimp contacts

The removal tool is inserted into a slot on the termination side of

the respective crimp cavity . This action compresses the contact re-

taining spring therefore the contact can then be easily withdrawn

using a light pull on the wire . This action will cause no damage to

the contact/wire which can be repositioned/refitted as necessary .

The drawing demonstrates the crimp removal procedure (max . 5x) .

W

or

king current

Ambient temperature

Removal tool

Mating conditions

see chapter 00

Coding systems

see chapter 00

Mounting clips

see chapter 00

Number of contacts

Type D

32

Type E

48

Contact spacing (mm)

Type D

5,08

Type E

male connector 5 .08 x 5 .08

male connector 2 .54 x 5 .08

female connector 5 .08 x 5 .08

Working current

6 A max .

see current carrying capacity chart 1 A max . for female

connector type E angled

Clearance

Types D and E

≥ 3 .0 mm

Type E male connector

≥ 1 .6 mm

row separation 2 .54 mm

Creepage

≥ 3 .0 mm

Working voltage

The working voltage also depends according to the safety

on the clearance and creepage

regulations of the equipment

dimensions of the pcb itself and

Explanations see chapter 00

the associated wiring

Test voltage U

r .m .s .

1 .55 kV

Contact resistance

≤ 15 mΩ

≤ 20 mΩ for female connector
type E angled

Insulation resistance

≥ 10

12

Ω for standard articles

≥ 10

11

Ω for special NFF articles (wi-

th part-no . ending 222)

Temperature range

– 55 °C … + 125 °C

The higher temperature limit

– 40 °C … + 105 °C

includes the local ambient and

for press-in connectors

heating effects of the contacts

under load

Degree of protection for crimp

IP 20

terminal

according to DIN 40 050

Electrical termination

Solder pins for pcb

connections Ø 1 .0 ± 0 .1 mm

according to IEC 60 326-3

Wrap posts 1 x 1 mm

diagonal 1 .34-1 .45 mm

Angled solder pins 1 x 1 mm

for pcb connections

Ø 1 .6 ± 0 .1 mm

Solder lugs

Crimp terminal 0 .09-1 .5 mm²

Compliant press-in

terminations

PCB thickness

≥ 1 .6 mm

Recommended PCB holes

see recommendation page 00 .25

for press-in technology

in acc . to EN 60 352-5

Insertion and withdrawal force

32 way ≤ 40 N

48 way ≤ 75 N

Materials

Mouldings

Thermoplastic resin,

glass-fibre filled, UL 94-V0

Contacts

Copper alloy

Contact surface

Contact zone

Selectively gold plated

according to performance

level

1)

1)

Explanation of performance levels see chapter 00

Advertising