Repair tooling, Instructions page 30.08 – Northern Connectors Harting DIN 41 612 Connectors User Manual
Page 203
30
.
07
To
ol
in
g
Repair tooling
· Instructions page 30.08
Identification
for use with
Part No.
Drawing
Dimensions in mm
Male
connectors
Type Q, 2Q,
3Q
R, 2R,
3R
Removal tool
for moulding
Insertion tool
for single male
press-in contacts
Removal tool
for single male
contacts
Termination
length
17 mm
Press-out tool
11.5 mm
13 - 13.2 mm
4.5 - 5.3 mm
Male
connectors
Type Q, 2Q, 3Q
R, 2R, 3R
Female
connectors
Type B, 2B, 3B
C, 2C, 3C
Female
connectors
Type F
Termination support
for protection
against bending
of 13 mm - 17 mm
terminations
Male
connectors
Type Q, 2Q, 3Q
R, 2R, 3R
SEK 18*
Female
connectors
Type B, 2B, 3B
C, 2C, 3C
F
Support block
for repair and removal
* Connectors see separate catalogue
Termination length [mm]
x [mm]
y [mm]
17
12 18.7
13 - 13.2
12
22.7
11.5
14 20.1
4.5 - 5.3
12
30.2
With the different dimension y no adjustment of hand