Iii i ii, High voltage contacts – Northern Connectors Harting DIN 41 612 Connectors User Manual

Page 65

Advertising
background image

01

.

39

IV

09 99 000 0194

III

III

09 99 000 0174

09 99 000 0328

09 99 000 0243

I

II

I

II

09 03 000 6140

09 03 000 6240

09 99 000 0196

IV

DIN

S

ig

na

l

up t

o 2 A

DIN 41 612 · Special contacts type M

Part No.

Identification

Performance level 1

Drawing

Dimensions in mm

High voltage contacts

High voltage male contact

for male connectors

2)

for straight solder

termination

2.8 kV

Impedance

50 Ω

75 Ω

Max. working frequency

0 up to 10 GHz

0 up to 1.5 GHz

Return loss

≥ 20 dB up to 6 GHz

≥ 20 dB

RF-leakage

≥ 80 dB up to 0.5 GHz

≥ 68 dB up to 1.5 GHz

Test voltage

750 V

rms

Working voltage

250 V

max.

Insulation resistance

≥ 1 GΩ

≥ 200 MΩ

Contacts resistance – Center contact

– Outer contact

≤ 10 mΩ

≤ 3 mΩ

Contact current max.

1.5 A

Admissible power (depends on: frequency, applica-

tion, return loss, environmental characteristics)

Data on request

acc. to DIN 41 626

Crimping tool

for coaxial contacts

Removal tool

incl. removal jacket
for contact replacement

in male and female connectors

Removal tool

for contact replacement

in male connectors

Replacement removal jacket

Electrical characteristics

of coaxial contacts

and wires

Crimping tool

for high current contacts

1)

Contact resistance max. 1.5 mΩ

2)

Contact resistance internal wire max. 3 mΩ

2.8 kV

High voltage female contact

for female connectors

2)

for straight solder

termination

Cable group 2

flexible wires

Impedance

Shell

ø

Screening

ø

Dielectric

ø

Internal wire

ø

Hexagonal crimp

Spanner width

RG 174 A/U

50 Ω

2.5

2.0

1.5

0.48

3.25

RG 188 A/U

50 Ω

2.6

2.0

1.5

0.54

3.25

RG 316 U

50 Ω

2.5

2.0

1.5

0.54

3.25

RG 179 B/U

75 Ω

2.54

2.0

1.6

0.3

3.25

Advertising