Ta rget p si real time – Precision Turbo and Engine NLR AMS-1000 Boost Controller User Manual

Page 14

Advertising
background image

14

STAGE TIME IN SECONDS—Time Based mode ONLY!,

This setting determines the Time

for Each Stage when using Time Based mode. To determine the total time for all stages add the Time
for each Stage together. Please see the example below for more details.

1

Select Cell for Editing.

2

Press the EDIT button.

3

Stage Time

Real Time

ESC, Exit
and do
NOT save
new value

SAVE, Exit
and Save
new value.

Adjust Value.

Ta

rget

P

si

Real Time

1

2

3

4

5

6

7

8

9

10

.5

1.0

.00

0

1.5

2.0

2.5

3.0

Stage1

Timer

Ramp1

Stage2

Timer

Ramp2

Stage3

Timer

Ramp3

Ramp4

Stage4

Timer

Activation

Holds until Activation

signal is removed.

RATE, PSI PER SECOND—All Modes,

This setting determines the Rate the Target Psi is ap-

plied. The range is 0 to 100 psi per second. A setting of 0 will apply the Target psi immediately with no
Ramp. The Ramp will be applied at the end of each stage when in Time Based mode.

When in Shift or GPS modes the Ramp will be applied on each gear change. If the Target psi is

not fully applied and a gear change occurs the Ramp rate for the next stage will be used.

An Optional delay timer is available in Shift mode only. This can be used to delay the Ramp for

1st gear only.

1

Select Cell for Editing.

2

Press the EDIT button.

3

ESC, Exit
and do

SAVE, Exit
and Save

new

Adjust Value.

Continued on next page...

Click for Index.

Back

Next

NOTE—Target Psi is the amount applied to the waste gate and is NOT the actual Manifold Boost Psi!