Precision Turbo and Engine NLR AMS-1000 Boost Controller User Manual

Page 15

Advertising
background image

15

TARGET PSI—All Modes,

This setting determines the Target Psi for each stage. The range of

Adjustment depends upon the MAP Sensor being used. The range is automatically scaled for current
MAP sensor selected. The Target Psi can be increased or decreased for each stage.

NOTE—It is possible to set a Target Psi value that can NOT be reached. This occurs when the Ramp
Rate and/or Stage Time does not permit the full Target Psi setting to achieved. i.e.—If a Stage Time of 1
second, Ramp Rate of 2 Psi Per Second, and a Target Psi of 4. The controller would only be able to ap-
ply 2 Psi in the 1 Second programmed for the stage. The only exception to this is the Last Stage. The
Last Stage Target Psi will always go to the programmed setting (unless the Activation signal is re-
moved).

1

Select Cell for Editing.

2

Press the EDIT button.

ESC, Exit
and do
NOT save
new value

SAVE, Exit
and Save
new value.

Adjust Value.

3

VOLTS, GPS INPUT VOLTAGE—GPS Mode ONLY,

The GPS voltage is used to determine

what gear the vehicle is in. The voltage for each gear position can be entered manually or a setup wiz-
ard is provided. A switch that provides a different voltage for each setting can be used to select up to 6
different boost profiles. The input will accept a +/-.1 volt input difference from the programmed value.
The current GPS Input Voltage and Gear Position will be displayed an the Main Screen when GPS
mode is active.

1

2

Manual setup.

Use Setup Wizard.

ESC, Exit
and do
NOT save

SAVE, Exit
and Save
new value.

Adjust Value.

GPS voltage, manual entry.

GPS Wizard Instructions,

To use the wizard simply put the vehicle in the gear displayed and press ENTER. Select

YES to accept the current Gps Voltage or NO to manually set the voltage. This option will only work
on vehicles that provide a voltage (0 to 5 volts) for each gear position. You may move through the
gear positions using the ARROW button.
Use

the

RANGE button to adjust the voltage +/- voltage range for the selected gear position.

Valid range is .1(.2 volt range) to .5(1 volt range) volts. It is common for the GPS voltage to change
vary with the engine running.
Press

the

DONE button when finished. If a voltage is present on the GPS (Activation) Input

that is not recognized the Target Psi will be set at 0.