MacDon M100 SP Operators Manual User Manual

Page 71

Advertising
background image

HEADER OPERATION

169304

69

Rev. C

6.4 HEADER

OPERATION

The M100 Windrower is designed to use the
MacDon A Series auger header with hay
conditioner, and D Series Rigid Draper headers
with or without hay conditioners. This section
describes the attachment and detachment
procedures and operating instructions for these
header types.

6.4.1

Header Lift Cylinder Stops

Cylinder stops are located on both header lift
cylinders on the windrower. To avoid bodily
injury or death from fall of raised header, always
engage cylinder stops before going under
header for any reason. Engage cylinder stops
as follows:

a. Press HEADER UP swich to raise header to

maximum height.

NOTE

If one end of the header does not raise
fully, the lift cylinders require re-phasing.
Proceed as follows:

1. Hold the up switch until both cylinders stop

moving.

2. Press

HEADER

DOWN

switch to lower the

header all the way down, and continue to
hold the switch for 3-4 seconds.

3. Raise the header again to full height.

b. Pull lever (A) and rotate toward header to

release and lower cylinder stop (B) onto
cylinder. Repeat for both lift cylinders.

c. To store, turn lever (A) away from header to

raise stop until lever locks into vertical position.

B

A

HEADER UP

HEADER DOWN

Advertising