105

MAINTENANCE/SERVICE

Traction Drive: Wheels and Tires


POWER HUBS

Check lubricant level every 200 hours or annually.
See "Fuels, Fluids and Lubricants" for
recommended lubricant.

Plugs (D) are located at 90° around wheel. To
check level, position wheel so plugs (D) are at the
12 o’clock (fill) and 3 o’clock (level) positions.
Lubricant should be level with plug at 3 o’clock.

Change power hub lubricant after the first 50 hours
operation and every 2000 hours (or annually)
thereafter. To drain lubricant, position wheel so
drain plug is at 6 o'clock position. Remove level
and drain plugs.


Power Hub Capacity
60 U.S. oz. (1800 mL)


IMPORTANT: Failure to disengage final drives
before towing will result in serious transmission
damage.





















CAUTION: With final drives disengaged, the windrower may roll on a sloped surface. Before
disengaging final drives, attach windrower to towing vehicle. After towing, engage drives
and lock steering wheel to engage park brake before detaching from towing vehicle.

To disengage final drives, remove cover (A) (both wheels) and reverse. Install with dished button facing in.
After towing, reverse covers again to re-engage final drives. See "Towing the Windrower".