MacDon 922 User Manual

Page 30

Advertising
background image

Form # 46620

Issue 01/06

28

OPERATION

AUGER MOUNTED CROP DEFLECTORS/STRIPPERS & STRIPPER BAR EXTENSIONS:

912 & 922 HEADERS

Four rubber finger assemblies are mounted to the auger to direct crop rearward to the hay conditioner such

that material is evenly distributed across the full width of the conditioner. If too much “end feeding” of

conditioner rolls is occurring, remove two outboard rubber finger assemblies (A).

If too much “Center Feeding” of conditioner rolls is occurring, the following may be necessary:

1. Install flighting-mounted deflectors (B). Deflectors are stored under platform at (C). Depending on crop

conditions, install one or two deflectors at each side of delivery opening.

2. Replace full-length front “L” angle strippers with 1/2 length front “C” channel strippers. These 1/2 length

strippers are stored on underside of pan at (D). On-header storage of full length front strippers is not

provided.

3. Remove center stripper extensions (E) on center stripper bars at each side of delivery opening.

E

CENTER STRIPPER EXTENSIONS

AUGER FLIGHTING DEFLECTOR

B

AUGER MOUNTED CROP DEFLECTORS

DEFLECTOR STORAGE

C

FRONT STRIPPER – SHORTER “C” CHANNEL

STRIPPER STORAGE

D

Advertising
This manual is related to the following products:

912