RECOMMENDED LUBRICANTS

GREASE

Use SAE Multi-Purpose High Temperature Grease with Extreme Pressure (EP) Performance and

containing at least 1.5% molybdenum disulphide. (NLGI Grade 2)

Also acceptable is an SAE Multi-Purpose Lithium Base Grease.

GEAR LUBRICANT

Wobble Box and Hay Conditioner Gear Case: Use SAE 85W-140 gear lube (API Service Class. GL-5)

Auger Drive Gear Case: Use grease as specified above.

CAPACITIES

Wobble Box – 2.2 litres (2.3 U.S. quarts)

Hay Conditioner Gear Case - 1100 ml (1.2 U.S. quart)

Auger Drive Gear Case - 600 grams (1.5 tubes)

STORING LUBRICANTS

Your machine can operate at top efficiency only if clean lubricants are used. Use clean containers to

handle all lubricants. Store them in an area protected from dust, moisture and other contaminants.

SEALED BEARING INSTALLATION

1. Clean shaft and coat with rust preventative.

2. Install flangette, bearing, flangette and lock

collar. The locking cam is only on one side of

the bearing.

3. Install (but do not tighten) the flangette bolts.

4. When the shaft is located correctly, lock the

lock collar with a punch. The collar should be

locked in the same direction the shaft rotates.

Tighten the setscrew in the collar.

5. Tighten the flangette bolts.

6. Loosen the flangette bolts on the mating

bearing one turn and re-tighten. This will allow

the bearing to line up.

TIGHTEN COLLAR IN DIRECTION

SHAFT ROTATES