Pw ps sw x – Retsch PT 200 User Manual

Page 26

Advertising
background image

Operating the machine

26

Fig. 6: Setting the opening width

The sub-sample is determined by the opening width of the sampling nozzle (PS) .

The maximum opening width(PS) in the standard bottom cone is 70 mm.

Loosen the two knurled screws (SW).

Set the opening width(X) by moving the slide (PW).

The scale on the bottom cone serves merely as an adjustment aid and does not
indicate the actual opening width(X).

The actual opening width(X) is measured in

the centre of the slot.

Once you have set the opening width, tighten the knurled screws again.

Pos : 6.35 /00005 Ü berschriften/1.1 Ü bersc hriften/1.1 Übersc hriften BD A/11 Öffnungs weite berec hnen @ 3\mod_1302780383889_9.doc @ 25113 @ 2 @ 1

5.15 Calculating the slot width

Pos : 6.36 /00010 Bedi enungsanleitung en Kapitels ammlungen/PT200 (2011)/0015 PT 200 Bedienung/1560 PT2 00 M odul Ber echnen der Öffnungs wei te @ 3\mod_1301576385198_9.doc @ 24523 @ 33 @ 1

5.15.1 Sample nozzle – Opening width

The calculation of the opening width (x) depends on the feed quantity( QA ) and
the required fraction (QT) at a fixed pitch circumference ( UK ) of 795 mm.

Key to symbols

UK = fixed pitch circumference

QA = I nitial quantity

QT = Fraction

X = Slot width

Example :

QA = 0.200 kg

QT = 0.010 kg

UK = 795 mm

Formula:

PW

PS

SW

X

Advertising