FPI FP90 Wood Fireplace

11

INST

ALLA

TION

Ventilated Chase Pan

Before You start

Check your inventory list to be sure you have all the necessary parts supplied in good usable

condition. Check for any concealed damage. Check the operation of the combustion air damper.

When the damper is in the fully closed position, the damper handle should be to the left. When

damper is in the fully open position, the damper handle must be in the right position.

installation coMponents diaGraM

installation components

note: insulation does not come in contact

with chimney. Maintain a 2" (51mm)

clearance.

installation

cHiMneY sYsteM

considerations

Regency’s FP90 Fireplace is to be installed with

one of the following Chimney Systems only.

Chimney systems only 8" (203mm) diameter

are to be used.

in u.s.a.

Any of the following air-cooled chimney systems

may be used:

1) Majestic SK8

2) Security FTF8

3) Superior TF8

4) Simpson DuraVent Dura-Plus

note: fireplace adaptor must be purchased

with fireplace when using air cooled. When

using duraplus, purchase adapter with

chimney system from chimney supplier.

The use of only one of these systems is permitted

when installing the fireplace. Do not alter or mix

parts from other systems as this may cause a

potential hazard and void Regency’s limited

warranty.

chimney Height

The total height of your chimney system from the

top of the fireplace to the chimney cap must not

exceed 40'(12m), and must also meet minimum

system height requirements. Please refer to

the flue manufacturer's instructions for specific

details. Refer to Minimum Recommended Flue

Height section.

chase enclosure

This unit requires the chase to be ventilated

with one 30 sq. inch vent. Refer to Installation

Measurements section.

A chase is a vertical box-like structure constructed

to surround the fireplace and chimney. A

ventilated chase cap is highly recommended.

Refer to flue manufacturer's instructions for

reduced flue heights above chase terminations.

As with all chimney installations, avoid overhead

obstructions such as trees, power lines, etc.

A chase should be constructed just like any

outside wall, insulated and vapor barriered.

Please check with local building authorities. In

a cold climate, we recommend the base of the

chase be insulated between the solid continuous

floor beneath the fireplace and the chase bottom.

If used, the value and amount of chase insulation

in a cold climate installation is optional and not

required for safety. Insulation is recommended

to avoid heat loss.

Insid

e W

all

Rain Cap

Storm Collar

Roof Flashing

Attic Radiation

Shield

Nailing Strip

Outside Fresh

Air Duct

Hearth

Extension

Hearth Safety

Strip

Outside Air

Inlet

Framing

Chase Vent Grill

Alternate Position

Chase Vent Grill