Installation, Wiring the fp90, Installing the blower systems – Regency Excalibur EX90 Large Wood Fireplace (US Edition) User Manual

Page 16: Gravity air feed kit option, Inst alla tion, Internal blower with thermo-disc

Advertising
background image

FPI FP90 Wood Fireplace

16

INST

ALLA

TION

Plan View

Jakel AX-2495 Blower

Angle View

Fan Transfer Plate

Right View

Front View

Fan 910-175 AX-3088

910-903

910-516

Ground

Neutral - from Fan

910-811

Thermodisc 910-142 P60T12

Variable Switch 910-330

919-885

Power Chord 910-619

Ground

Hot - to Va

riable Switc

h

side. Duct must be secured by screws or

clamp.

WirinG tHe fp90

Field wire main power supply to fireplace blower

system. (All electrical connections should only

installation

caution: label all wires prior to

disconnection when servicing controls.

Wiring errors can cause improper and

dangerous operation.

be performed by a licensed/certified electrician).

installinG tHe

BloWer sYsteMs

The FP90 Fireplace has been designed to

meet a wide range of heating requirements.

The radiant heat (through the large glass area)

combined with the naturally convected heat,

allows the FP90 Fireplace to adequately heat an

average sized room. A blower is recommended

to assist in heating a larger area or one with

wall separations.

internal Blower with thermo-disc

The thermodisc provides the user with more convenient control. The fan operates automati-

cally - turn the knob to adjust to desired speed. The fan will turn on as the stove comes up to

operating temperature. After the fire cools to below a useful heat output range the fan will shut

off automatically.

Place sticker on outside of bottom louver.

GraVitY air feed Kit option

The Gravity Air Feed Kit is designed to extend the heat output vent above the FP90 to the

front or the side. The upper louver opening is blocked off and flex vent is connected to the

vent holes in the top of the unit and run to discharge vent grilles. Both 8" (203mm) diameter

insulated Flex vents must be used along with one 30 sq. inch (194cm

2

) chase vent grill to

bring additional air into the chase (for U.S. installations only).

Qty

Description

4

Connector Collars

4

Adjustable Clamps

2

5’ lengths of flexible vent pipe

(8” dia.)

2

Insulated Sleeves

1

Block Off Plate

2

Discharge Vent Mounting Frames

7

1/4-20 x 1/2” Truss Head Screws

(used for EX90/R90 only)

2

16 x 8 Discharge Vent Grilles

4

#8 Drywall Anchors

4

Insulation Strips

1

Chase Vent Frame

(not required for FP90)

1

8 x 8 Chase Vent Grille

(not required for FP90)

Discharge Vent

Grill

Chase Vent

Grill

30 sq.in. (194 sq.cm)

opening

Alternate Position for

Chase Vent Grill

Block-off Plate

(replace top louver)

Base of Stove

Vent Cover 'B'

(Inside)

Vent Cover 'A"

Center-line

of Vent

6" (152mm) Min.

To Rouch Opening

Ceiling

Flue

Flex Vent

Clamp

Connector

Collar

Connector

Collar

Outside Air

Intake

Insulation

Strips