FPI FP90 Wood Fireplace

15

INST

ALLA

TION

installation

installinG tHe

outside air Kit

Combustion air is fed to the firebox through a

connection on the rear lower left side of the unit.

A free flowing supply of air must be available to

this opening at all times. Combustion air may be

taken from inside the building if the local building

code allows, but performance may suffer. Also,

it must go through the 6" (152mm) duct to the

connection on the left hand side.

Air drawn from the interior of the building will

affect the performance of gas or oil furnaces,

and exhaust fans and fan driven appliances.

Outside Air Inlet must be 6 ft. (152mm) below

the chimney termination point

Insulated Metal

6” Duct

Exterior

Wall

Outside

Metal

Vent

Side Connection

Unit

This may cause a negative pressure in the

house allowing smoke to back into the home.

The preferred source of combustion air is from

outside the building. If possible, install the kit

on the wind loading side of the building not the

leeward or (negative pressure) side.

note: do not obtain combustion air from

attic, garage or other enclosed

space.

1) Put the supplied insulated air duct to a nearby

exterior wall. Maximum length of duct is 20ft

(6.1m). Duct length should be kept to a

minimum and as straight as possible.

note:

4 ft. only is supplied with unit. Termination

should be in an area with good air flow.

2) Ensure that your air source is not close to

automobile exhaust, gas meters or other

vents.

3) Cut a 7" (178mm) hole through the wall and

mount the outside air kit.

4) Attach the two ends of the duct (making

sure not to damage the insulating cover)

after installing the flange on the fireplace

taBle 1

required firestop,

radiation shield, or

attic insulation shield

MODEL

1st FLOOR

2nd FLOOR INTO ATTIC

Superior TF8

Joist Shield Firestop

Attic Shield Firestop

Majestic SK8

Joist Shield Firestop

Attic Shield Firestop

Security FTF8

Joist Shield Firestop

Attic Shield Firestop

Simpson DuraVent

Dura-Plus

Intermediate Joist/

Radiation Shield

Attic Radiation Shield

taBle 2

Minimum recommended flue Height in feet

(Measured from the top of the solid fuel appliance)

eleVation (ft)

aBoVe sea leVel

# of elBoWs

0

2 x 15

o

4 x 15

o

2 x 30

o

4 x 30

o

0-1000

12.00

13.00

14.00

15.0

18.00

1000-2000

12.48

13.52

14.56

15.6

18.72

2000-3000

12.96

14.04

15.12

16.2

19.44

3000-4000

13.44

14.56

15.68

16.8

20.16

4000-5000

13.92

15.08

16.24

17.4

20.88

5000-6000

14.40

15.60

16.80

18.0

21.60

6000-7000

14.88

16.12

17.36

18.6

22.32

7000-8000

15.36

16.64

17.92

19.2

23.04

8000-9000

15.84

17.16

18.48

19.8

23.76

9000-10000

16.32

17.68

19.04

20.4

24.48