Installation, Fp90, Fan installation – Regency Excalibur EX90 Large Wood Fireplace (US Edition) User Manual

Page 22: Inst alla tion

Advertising
background image

FPI FP90 Wood Fireplace

22

INST

ALLA

TION

installation

fan installation

05/12/11

918-437

FP90

FAN INSTALLATION

NOTE: If optional Ashtray is installed, it must be removed before installing the fan.

The receptacle Box must be replaced with one that will accept the fan cable.

1) Remove the thumb screw from the fan transfer tray.
2) Slide fan transfer tray fully out through the bottom louver opening.
3) Mount the fan bracket onto the fan transfer tray using the two locating pins (see Diagram 1).

4) Slide the Control Switch Box onto the Control Switch Box Mounting Bracket located on the front of the fan transfer tray and

secure with the #8 x 3/8” screw provided (refer to Diagram 1).

5) Secure wiring to fan tray with supplied strain reliefs.

See Diagram 3.

6) Secure both ground wires to ground lug. Bolt onto unit.

7) Plug fan into receptacle box (see note at

top of page).

8) Slide thermodisc into position

(which is located under the fi rebox).

9) Reinstall the thumb screw.

Diagram 4

Diagram 3

Thermodisc

Strain Reliefs

F

F

THERMODISC

M

M

FAN

M

F

M

F

SWITCH CONTROL BOX

HI

OFF

LOW

GROUND

POWER CORD

WHIT

E

BLACK

RED

GREY

WHIT

E

BLUE

M

F

GREY

GREEN

BROWN

GROUND

GREEN

Diagram 2

Diagram 1

Fan transfer tray

Thumb Screw

Control Box
mounting bracket

Control
Box

Locating Pins