Scan adaptation – Barco R9002031 User Manual

Page 13

Advertising
background image

Installation setup

4-2

5975607 BARCODATA 808s 170397

Scan Adaptation

The scan switches must be placed in the correct position which corresponds to the desired scanning configuration.

To change the scanning, it is necessary to remove the projector top cover and to open the protection plate.

For opening the projector's top cover, see 'Access to controls'.

WARNING !

TURN OFF PROJECTOR AND UNPLUG THE POWER

CORD BEFORE CHANGING THE SCAN DIRECTION.

- Repeat this action on both sides of the module and extract the

module out of the main frame.

Side view

Top view

Top view

Side view

Push

Three switches are used, one for each CRT. When changing the

horizontal scan, insure that all three switches are set in the same

position. See positions of the switches (diagram on next page) for

the corresponding projector configuration.

To set the scan switches :

•

Remove the horizontal deflection module (the second module
viewing from the rear of the projector).
To remove the horizontal deflection module :
- Press the module lock and lift up the module handle;

Horizontal deflection module

•

Toggle the 3 horizontal scan inversion switches (located just
underneath the horizontal amplitude module) to the correct

positions (see p.4-3).

•

Reinstall the horizontal deflection module.

•

Open the top cover and remove it from
the projector (see p.4-1);

•

Loosen the 3 retaining screws on each
side of the projector;

•

Open the protection plate and pivot it
forward (toward lenses).

Getting access to the scan switches

Horizontal scan switches

Horizontal amplitude

module

Connectors for the

horizontal deflection module

Horizontal Scan Switches

Advertising