Off on 0 1, Baud rate for communication with a computer, Password mode – Barco R9002031 User Manual

Page 18

Advertising
background image

Projector setup

5-3

5975607 BARCODATA 808s 170397

Position of DIP switches and baud rate codes :

Baud Rate for communication with a

computer

The communication speed between the projector and the computer

has 8 possible settings. With DIP Switch No. 6, No.7 and No.8 of the

8 DIP switches on the controller board, labelled as ‘Baud rate code

(sum)’, it is possible to select the baud rate (communication speed).

Each DIP switch has its own decimal value. The sum of the values

associated to those DIP switches gives the baud rate code. Each

baud rate code corresponds an communication speed.

1
2
3

4
5
6
7
8

OFF ON

0

1

Baud rate

DIP switches

4
2
1

Password mode

With DIP Switch No.5 of the second set of 8 DIP switches on the

controller board, the projector adjustments can be protected with a

password. When the password feature is enabled, the user has to

enter a password before he can enter the adjustment mode (For more

information about password setting and reprogramming the pass-

word, see Installation Adjustment).

When the password menus are disabled (adjust mode is unpro-

tected), the adjust mode can be selected by pressing the <ADJUST>

key. This position of the DIP switch is useful for qualified service

technicians because they do not need a password to enter the adjust

mode.

Position of DIP Switch No.5 :

ON : password mode enabled.
OFF : password mode disabled.

Factory preset password mode : OFF.

Factory preset baud rate = 9600

More information about computer communication with the

BARCOGRAPHICS 808s is available in the Projector Control Soft-

ware manual.

Password

mode

1
2
3

4
5
6
7
8

OFF ON

0

1

Binary Baud rate code Speed

000

0

110

001

1

150

010

2

300

011

3

600

100

4

1200

101

5

2400

110

6

4800

111

7

9600

Advertising
This manual is related to the following products: