Multi-phase design guide, Programming synchronization delay – Vicor PI33XX-XX Multi-Phase Design Guide User Manual

Page 3

Advertising
background image

vicorpower.com Rev 1.0

Cool-Power

®

800 735.6200 11/2012 Page 3 of 4

Multi-Phase Design Guide

Programming Synchronization Delay

The PI33XX-2X provides an I

2

C

TM

Standard Mode

digital interface that enables the user to
program phase delays. This is a one-time
programmable option to the device. To set a
delay, the user needs to assign a unique Device
Address (see Table 2) to wake up the device
during

programming.

Then

send

the

synchronization delay address (21h) and the
delay data (OEh) while adhering to I

2

C protocols

and Figure 4 sequencing.

The following figure demonstrates the proper
steps to program a single phase-delay. The
device address is determined by the user and
the synchronization delay is provided in Table 1.
The device address is represented as XXh (Bold)
in Figure 6. Because this process in not
reversible, it is important to follow all steps in
Figure 4.


1) Clear all Registers to 00h with the device enabled

Start

Addr.

Device

Wr

Ack

Addr.

Reg

Ack

Data

Ack

Stop

S

XXh

1

0

20h

0

00h

0

P

S

XXh

1

0

21h

0

00h

0

P

S

XXh

1

0

22h

0

00h

0

P

2) Enter Test Mode 5

Start

Adr.

Device

Wr

Ack

Adr.

Reg

Ack

Data

Ack

Stop

S

XXh

1

0

18h

0

05h

0

P

3) Disable then Re-enable the Device (Enable Pin)

4) Set Desired Delay

Start

Adr.

Device

Wr

Ack

Adr.

Reg

Ack

Data

Delay

Ack

Stop

S

XXh

1

0

21h

0

0Eh

0

P

5) Disable Device (Enable Pin)

6) Return to Test Mode 0

Start

Adr.

Device

Wr

Ack

Adr.

Reg

Ack

Data

Ack

Stop

S

XXh

1

0

18h

0

00h

0

P

7) Repeat 1); Clearing all Registers

8) Enable Device (Enable Pin); Programming is Complete

Figure 4 - Showing the 8 Steps Required to Program a Single 1/3 Phase Delay

Advertising