Explanation of the functions (part 2) function 4, Function 5, Function 6 – Waldmann PULSE HFMD version VFC III - with MFT User Manual

Page 17

Advertising
background image

17

GB

Operating Manual Light control “PULSE HFMD - Vers. III“

GB

Operating Manual Light control “PULSE HFMD - Vers. III“

Explanation of the functions (part 2)

Function 4

Write protection

Function to admit or prevent setting

variations.

The default setting of the function

is “OFF“, i.e., the set levels can be

overwritten at any time.

The levels cannot be changed if the

write protection is active.

The function can be changed on

lights with sensors XXX /P

Function 5

Light control

Function for the automatic readjus-

tment of the set brightness in case

the ambient brightness changes.

The default setting of this function

is “ON”, i.e., the light control is

active.

If the light control is switched off,

the light functions as a dimmable

light.

The function can be changed on

lights with sensors XXX /P

Function 6

Presence control

Function to detect the presence

of persons.

The default setting of this function

is “ON”, i.e., the presence control

is active.

If the function is switched on, the

light automatically switches off, if

for a certain time no presence is

detected.

If the presence control is switched

off, the light functions as a light

with light control or as a dimmable

light.

The function can be changed on

lights with sensors XXX /P

Fig. 3