8

GB

Operating Manual Light control “PULSE HFMD - Vers. III“

GB

Operating Manual Light control “PULSE HFMD - Vers. III“

Change basic settings

Change to
parameterization mode

- Keep both keys [I and II] pressed

simultaneously for 2 seconds.

- The operating panel changes to

the parameterization mode (fi rst

to level 1).

- The background lit logo fl ashes

(once per second).

- In order to jump to a higher level,

both keys [I and II] have to be

held pressed until the logo stops

fl ashing (level 2) or until the logo

starts fl ashing again (level 3).

Change setting

The individual functions are selec-

ted via key II.

The light bar shows the selected

function.

The LED on the light bar indicates

whether a function is active (ON)

or inactive (OFF) by permanent

lighting or fl ashing, e.g.:

- LED constant dark green:

Function 1 active (On)

- LED fl ashing dark green:

Function 1 inactive (OFF)

The function can be activated or

deactivated by pressing the key I.

The parameterization mode is

left if no key has been pressed

for 10 seconds. The settings are

stored.

Fig. 4

Fig. 3

Key I

Logo

Light

bar
Key II

LED I

LED II

LED II

Key II

LED I

Key I

Sensor

- The LEDs [I and II] on the sen-

sor operating panel (see Fig. 4)

fl ash - according to the level) in

the respective color (once per

second):

LED II fl ashing white:

Level 1

- LED I and II fl ashing green:

Level 2

- LED I and II fl ashing blue:

Level 3