Step 1: remove power from the drive – Rockwell Automation 20D Stegmann Feedback Option Board for PowerFlex 700S Drives User Manual
Page 3
 
Stegmann Feedback Option Board for PowerFlex® 700S Drives
3
Step 1: Remove Power 
from the Drive
1. Turn off and lock out input power. Wait five minutes.
2. Verify that there is no voltage at the drive’s input power terminals.
3. Measure the DC bus voltage at the DC+ & DC- terminals on the Power
Terminal Block. The voltage must be zero.
!
ATTENTION: To avoid an electric shock hazard, verify that the 
voltage on the bus capacitors has discharged before performing 
any work on the drive. Measure the DC bus voltage at the DC+ & 
DC- terminals of the Power Terminal Block. The voltage must be 
zero.
Remove power before making or breaking cable connections. 
When you remove or insert a cable connector with power 
applied, an electrical arc may occur. An electrical arc can cause 
personal injury or property damage by:
•
sending an erroneous signal to your system’s field devices, 
causing unintended machine motion
•
causing an explosion in a hazardous environment
Electrical arcing causes excessive wear to contacts on both the 
module and its mating connector. Worn contacts may create 
electrical resistance.
L1
L2
L3
O
I