Step 6: install the new field circuit board – Rockwell Automation 20P PowerFlex DC Drive - Frame A Field Circuit Board User Manual

Page 18

Advertising
background image

18

PowerFlex® DC Drive - Frame A Field Circuit Board

Step 6: Install the New
Field Circuit Board

Install the new Field board in reverse order of removal as detailed in Step 5:

Remove the Existing Field Circuit Board on page 13

.

1. Replace the cable connected to XFCD on the Field board with the new

cable provided.

2. Verify that the field circuit wires are connected to the correct location

on the Field SCR/Dual Diode Bridge module.

Step 7: Install the Pulse
Transformer and Switching
Power Supply Boards

Install the Pulse Transformer and Switching Power Supply boards in reverse
order of removal as detailed in Step 4:

Remove the Pulse Transformer and

Switching Power Supply Boards on page 7

.

Step 8: Install the Control
EMI Shield and Control
Board

Install the Control EMI Shield and Control board in the reverse order of
removal as detailed in Step 3:

Remove the Control EMI Shield and Control

Board on page 6

.

ATTENTION: Failure to install the Isolation sheet below the
Field board may result in damage to the drive.

Blue wire from 2D1
on Field board

Red wire from 2C1
on Field board &
Thin Red Wire from
XP on Pulse
Transformer board

Black wire from
2V1 on Field board

Brown or Green wire
from 2U1 on Field board

ATTENTION: Each gate lead cable must be connected to the
exact connector from which it was removed on the Pulse
Transformer circuit board or damage to the drive may occur.

Advertising