Rockwell Automation 20P PowerFlex DC Drive - Frame C Switching Power Supply Circuit Board Fuses User Manual
Page 4
![background image](/manuals/576947/4/background.png)
4
PowerFlex® DC Drive - Frame C Switching Power Supply Circuit Board Fuse Replacement
7. Loosen the two captive screws at the top of the Control EMI shield and
partially lower the shield. The shield will not open to its full extent due
to a cable connection between the Switching Power Supply board and
the Pulse Transformer board.
8. Disconnect the cable from connector XSW on the Switching Power
Supply board and lower the Control EMI shield until it rests on the
drive chassis.
Important: If the drive is not in a vertical position, the Control EMI
shield will not stay open without a means of restraint.
9. Remove the two fuses on the Switching Power Supply board by
inserting a screwdriver in the slot on the top of the fuse, carefully
pushing down and turning the fuse counterclockwise. When the fuse
holder releases, remove the holder and fuse.
Loosen screws
Remove cable