PowerFlex® DC Drive - Frame C Switching Power Supply Circuit Board Fuse Replacement

7. Loosen the two captive screws at the top of the Control EMI shield and

partially lower the shield. The shield will not open to its full extent due
to a cable connection between the Switching Power Supply board and
the Pulse Transformer board.

8. Disconnect the cable from connector XSW on the Switching Power

Supply board and lower the Control EMI shield until it rests on the
drive chassis.

Important: If the drive is not in a vertical position, the Control EMI

shield will not stay open without a means of restraint.

9. Remove the two fuses on the Switching Power Supply board by

inserting a screwdriver in the slot on the top of the fuse, carefully
pushing down and turning the fuse counterclockwise. When the fuse
holder releases, remove the holder and fuse.