Rockwell Automation 20P PowerFlex DC Drive - Frame B Bimetal Thermostat User Manual
Page 3
Advertising
![background image](/manuals/577022/3/background.png)
PowerFlex® DC Drive - Frame B Bimetal Thermostat
3
Step 2: Remove the
Protective Covers and
Power Wiring
1. Remove the screws and washers that secure the plastic shields to the
bottom of the drive and remove the shields.
2. Remove the bolts, washers and wiring from the U phase AC input and D
power terminals.
3. Disconnect the DPI cable from the HIM assembly (if present).
4. Loosen, but do not remove, the screws that secure the bottom cover to
the drive, then slide the cover down and off the drive chassis.
Remove screws and shield
Remove screws and shield
U Phase
D Terminal
Remove bolts and wiring
Bottom View
=
Disconnect
DPI cable
Tightening torque:
1.5 N•m (13.3 lb•in)
Advertising