Rockwell Automation 20P PowerFlex DC Drive - Frame B Pulse Transformer Circuit Board User Manual

Page 16

Advertising
background image

16

Rockwell Automation Publication 20P-IN009D-EN-P - February 2012

PowerFlex DC Drive Frame B Pulse Transformer Circuit Board

Pulse Transformer Board FIR2-XX Rev. “N” and Higher

Set DIP switches S3 and S4, located at the bottom right corner of the Pulse
Transformer board (see

Figure 1 - on page 5

for location), to the correct settings

based on the appropriate table below.

Table 5 - 230V AC Input Drives

Table 6 - 460V AC Input Drives

XSW1

XI2CA

X3

XP

TR2

TR1

XR

X4

XY

XCD_IO

TO5

TO3

TO6

TO1

TO4

TO2

KGO1

KGO4

KGO2

KGO5

KGO3

KGO6

T5

T3

T6

T1

T2

KG1

KG4

KG2

KG5

KG3

KG6

XCT

C

U

PE

PE1

V

XTA

XM

D

78 79 35 36 75 76 U2 V2

W

S3

S4

1U2 1V2

T4

1

D

79 35 36 75 76 U2 V2

S3

S4

1

Dip switches S3 and S4 are located at
the bottom, right corner of the board.

IMPORTANT

A blank cell below a switch in the following tables indicate that the setting is
“OFF”.

Drive

Current

Rating

Code

DC

Amps

AC Line

Amps

HP

DIP Switch S3

DIP Switch S4

S3-1

S3-2

S3-3

S3-4

S3-5

S3-6

S3-7

S3-8

S4-1

S4-2

S4-3

S4-4

S4-5

S4-6

S4-7

S4-8

146

146

119

40

ON

ON

ON

180

180

147

50

ON

ON

ON

ON

218

218

178

60

ON

ON

ON

ON

265

265

217

75

ON

ON

ON

ON

360

360

294

100

ON

ON

ON

434

434

355

125

ON

ON

ON

ON

Drive

Current

Rating

Code

DC

Amps

AC Line

Amps

HP

DIP Switch S3

DIP Switch S4

S3-1

S3-2

S3-3

S3-4

S3-5

S3-6

S3-7

S3-8

S4-1

S4-2

S4-3

S4-4

S4-5

S4-6

S4-7

S4-8

167

167

136.4

100

ON

ON

ON

ON

207

207

169.1

125

ON

ON

ON

250

250

204.3

150

ON

ON

ON

ON

330

330

269.6

200

ON

ON

ON

412

412

336.6

250

ON

ON

ON

ON

Advertising