Second Encoder Option Card for PowerFlex® 700S Drives with Phase II Control
Dip Switch Settings
Dip switch S1 configures the power supply output voltage and the encoder 
interface input voltage. Almost all applications require you to set all four 
switches on the assembly to either 5V dc or 12V dc. 
Step 11: Replacing the 
Covers and Control 
Cassette
The procedure for replacing the covers and control cassette is the reverse of 
removing these components. Refer to 
EtherNet/IP Option Card on page 6
,
Step 5: Removing the Outside Covers
from the Control Cassette on page 5
Step 4: Removing the Inside Cover
from the Control Cassette on page 5
OPEN
1
FRONT - TOP VIEW
SIDE VIEW
UP = OPEN = OFF
DOWN = CLOSED= ON
S1
2 3 4
Voltage 
Selection
S1-1
(Supply)
S1-2
(A Channel)
S1-3
(B Channel)
S1-4
(Z Channel)
5V dc
Closed
Closed
Closed
Closed
12V dc
Open
Open
Open
Open