Step 11: replacing the covers and control cassette – Rockwell Automation 20D-P2-ENCO PowerFlex 700S Drive Phase II Control Second Encoder Option Card User Manual

Page 10

Advertising
background image

10

Second Encoder Option Card for PowerFlex® 700S Drives with Phase II Control

Dip Switch Settings

Dip switch S1 configures the power supply output voltage and the encoder
interface input voltage. Almost all applications require you to set all four
switches on the assembly to either 5V dc or 12V dc.

Step 11: Replacing the
Covers and Control
Cassette

The procedure for replacing the covers and control cassette is the reverse of
removing these components. Refer to

Step 7: Removing the Embedded

EtherNet/IP Option Card on page 6

,

Step 5: Removing the Outside Covers

from the Control Cassette on page 5

,

Step 4: Removing the Inside Cover

from the Control Cassette on page 5

and

Step 3: Removing the Control

Cassette from Drive on page 4

.

OPEN

1

FRONT - TOP VIEW

SIDE VIEW

UP = OPEN = OFF

DOWN = CLOSED= ON

S1

2 3 4

Voltage
Selection

S1-1
(Supply)

S1-2
(A Channel)

S1-3
(B Channel)

S1-4
(Z Channel)

5V dc

Closed

Closed

Closed

Closed

12V dc

Open

Open

Open

Open

Advertising