What you need to do – Rockwell Automation 20D-P2-ENCO PowerFlex 700S Drive Phase II Control Second Encoder Option Card User Manual
Page 2

2
Second Encoder Option Card for PowerFlex® 700S Drives with Phase II Control
What You Need to Do
To remove the Second Encoder Option Card from a PowerFlex 700S drive:
❐ Step 1: Remove power from the drive
❐ Step 2: Open the main drive door
❐ Step 3: Remove the control cassette from the drive
❐ Step 4: Remove the inside cover from the control cassette
❐ Step 5: Remove the outside covers from the control cassette
❐ Step 6: Remove the old Second Encoder Option Card and Stacker
Connector
❐ Step 7: Remove the Embedded EtherNet/IP Option Card
❐ Step 8: Install the two-pin jumper
To replace the Second Encoder Option Card from a PowerFlex 700S drive:
❐ Step 8: Remove remove the two-pin jumper
❐ Step 9: Install the Stacker Connector and new Second Encoder
Option Card
❐ Step 10: Wire and configure the Second Encoder Option Card
❐ Step 11: Replace the covers and control cassette
❐ Step 12: Document revision changes
To return replaced Second Encoder Option Card, use packing material from
the new Second Encoder Option Card.