97d01891, Cu s t omer terminal s – Rockwell Automation 23C PowerFlex 400 AC Drive Packages for Fan & Pump Apps User Manual

Page 117

Advertising
background image

Rockwell Automation Publication 23C-IN001B-EN-P - June 2013

117

3 Contactor Full Feature Bypass with Disconnect Package (Style B/N)

Chapter 2

Figure 86 - 250…350 Hp, 460V AC Drives - NEMA/UL Type 1

97D01891

01

02

0

3

04

05

06

07

0

8

09

10

11

12

1

3

14

15

16

17

1

8

19

20

21

22

2

3

24

25

26

27

2

8

29

3

0

3

1

3

2

33

3

4

3

5

3

6

3

7

38

3

9

40

41

42

02

0

3

04

05

06

07

0

8

09

10

11

12

1

3

14

15

16

17

1

8

19

20

21

22

2

3

24

25

26

27

2

8

29

3

0

3

1

3

2

33

3

4

3

5

3

6

3

7

38

3

9

40

41

42

01

DA

T

E

REV

.

BY

ECN/CR.

NO

.

APPR

O

V

AL

DE

S

IGN REVIEW

FOR MANUF

A

CTURING

A

S

S

HIPPED

A

S

COMMI

SS

IONED

BY

DA

T

E

S

H.

NEXT

NO

.

S

H.

-

DW

G

.

ENG.

TITLE

CHK.

BY

NO

.

DA

T

E

DA

T

E

DR.

BY

DA

T

E

THI

S

DRA

WING I

S

THE PR

OPER

TY OF R

OCKWELL A

UT

OMA

TION, INC

.

OR IT

S

S

UB

S

IDIARIE

S

AND MA

Y NO

T BE COPIED

, U

S

ED OR DI

S

CLO

S

ED FOR ANY

PURPO

S

E EXCEPT A

S

A

UTHORIZED IN

WRITING BY R

OCKWELL A

UT

OMA

TION, INC

.

1

1

INTER-CONNECT DRA

WING (CIRCUIT BREAKER)

PF400, 250-

3

50HP/460V

A

C

, NEMA1

S

TYLE B

, FRAME

S

G & H, CONTR

OL

97D01

8

91

REH/A

CI

10/9/06

A

WR/A

CI

10/9/06

A

WR/A

CI

10/9/06

L

3

INCOMING

3

f

PO

WER

L2

L1

CONNECTION

S

S

UPPLIED BY CU

S

T

OMER

WILL REQ

UIRE MANU

AL RE

S

ET

.

OPENING OF

THE FREEZE/FIRE INTERLOCK

1

MAIN

CIRCUIT

BREAKER

T2

T1

T

3

G

3

2

3

1

33

3

4

3

5

3

6

3

7

38

3

9

CU

S

T

OMER TERMINAL

S

BC

BYP

A

SS

RU

N

PURGE

40

AUT

O S

T A

RT

BYP A

SS

STA

TU

S

INTERLOCKS

FREEZW/FIRE

T1

T2

T

3

M

OTO

R

R/L1

T/L

3

S

/L2

GP

2

P1

U/T1

PO

WERFLEX 400

W/T

3

V/T2

S

PEED REF

. INPUT

0

T

O +10VDC

, 100K

OHM

INPUT IMPED

ANCE

2

+

S

PEED REF

. INPUT

4-20MA, 250 OHM

INPUT IMPED

ANCE

+

2

PO

38

[

S

PEED REFERENCE] =

3

"ANALOG In2".

WIRE

T

O ANALOG INPUT #2 AND CHANGE P

ARAMETER

INPUT #1.

IF 4-20mA

S

OURCE I

S

T

O BE U

S

ED

,

COME FR

OM 0-10V

S

OURCE WIRED

T

O

ANALOG

WHEN IN "A

UT

O MODE"

S

PEED REFERENCE

WILL

2

10V 20MA

RUN/FWD

FUNCTION LOSS

SOFTW

ARE ENABLE

DIGIT AL INPUT 1 (PURGE)

DIGIT AL COMMON

DIGIT AL INPUT 2 (LOCAL)

DIGIT AL INPUT

3 (CLEAR F

AUL

T)

DIGIT AL COMMON

DIGIT AL INPUT 4 (COMM POR

T)

1

3

24

7

56

8

9

10V 20MA

CONTR

OL BO

ARD

AO

2

10V 20MA

A

O1

AI1

ANALOG COM. #1

ANALOG OUTPUT #2 (OUTPUT CURRENT 0-10V)

ANALOG OUTPUT #1 (FREQUENCY 0-10V)

ANALOG INPUT #1

+ 10VDC

+ 24VDC

ANALOG INPUT #2

#1 RELA Y N.O

. (READ

Y/FA

UL T)

ANALOG COM #2

OPTO OUTPUT (A

T FREQUENCY)

#1 RELA Y COMMON

#1 RELA Y N.C

.

#2 RELA Y N.O

. (MO

TOR R

UNNING)

#2 RELA Y COMMON

#2 RELA Y N.C

.

RJ-45 S

HIELD

OPTO COMMON

15

11

10

12

1

3

14

16

17

19

1

8

20

R

3

R1

R2

R4

R5

R6

S

RC

10V 20MA

AI2

S

NK

DM1

CB1

Advertising