95d01580, Drive, Purge – Rockwell Automation 23C PowerFlex 400 AC Drive Packages for Fan & Pump Apps User Manual

Page 137: Byp ass ru n test byp ass drive, Trip byp ass

Advertising
background image

Rockwell Automation Publication 23C-IN001B-EN-P - June 2013

137

3 Contactor Full Feature Bypass with Disconnect Package (Style B/N)

Chapter 2

Figure 106 - 3.0…10 Hp, 208V AC & 3.0…20 Hp, 460V AC Drives - NEMA/UL Type 12

95D01580

01

02

03

04

05

06

07

08

09

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

02

03

04

05

06

07

08

09

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

01

DA

T

E

REV

.

BY

ECN/CR.

NO

.

A

2/3/06

REH

B

8/3/06

JCL

C

11/15/06

REH

D

12/22/06

REH

E

6/20/08

ALB

F

6/22/2011

DJK

G

4/3/12

JCK

APPR

O

V

AL

DESIGN REVIEW

FOR MANUF

A

CTURING

AS SHIPPED

AS COMMISSIONED

BY

DA

T

E

SH.

NEXT

NO

.

SH.

-

DW

G

.

ENG.

TITLE

CHK.

BY

NO

.

DA

T

E

DA

T

E

DR.

BY

DA

T

E

THIS DRA

WING IS

THE PR

OPER

TY OF R

OCKWELL A

UT

OMA

TION, INC

.

OR ITS SUBSIDIARIES AND MA

Y NO

T BE COPIED

, USED OR DISCLOSED FOR ANY

PURPOSE EXCEPT AS A

UTHORIZED IN

WRITING BY R

OCKWELL A

UT

OMA

TION, INC

.

1

1

LA

Y

OUT DRA

WING

PF400, FRAME C

, STYLE B

, 3-10HP @ 208V

A

C

, 3-20HP @ 480V

A

C

NEMA 12

95D01580

REH/A

CI

11/21/05

JCL/A

CI

02/23/06

JFH

11/21/06

TB2

TB1

T1

MG

T2

T3

40

39

38

37

36

35

34

33

32

31

MTR GR

OUND

OUTPUT PO

WER

TERMINAL BLOCK

SPEED

MANU

AL

1

2

3

4

5

6

7

8

9

10

0

P1

TH1

CB1

L1

L2

L3

CIRCUIT BREAKER

OPTIONAL

43

14

NO

13

44

NO

BC

6

T3

4

T2

T1

5

L3

L2

3

L1

43

14

NO

13

44

NO

43

14

NO

13

44

NO

43

14

NO

13

44

NO

DIC

DOC

14

NO

4

T1

T3

6

T2

13

NO

5

3

L1

L2

L3

NO

2

4

14

T3

6

T2

NO

1

13

5

3

L2

L3

2

T1

L1

1

2

1

OL

TB2

TB1

32
31

34
33

36
35

38
37

40
39

T1

T3

T2

MG

SECOND

AR

Y

PRIMAR

Y

100V

A

FU4

TA-2-69301

FU5

X2

F2

F1

X1

H1

H3

H2

H4

INTERLOCK

OPEN

READ

Y

SEE DRIVE DISPLA

Y

DRIVE

FOR DRIVE ST

A

TUS

OUTPUT

ENABLE

HAND

MO

T

OR

AU

T

O

MO

T

OR

OFF

DOC

DRIVE

DIC

PURGE

DRIVE

BYP

ASS

RU

N

TEST

BYP

ASS

DRIVE

BC

OL

TRIP

BYP

ASS

FR

ONT VIEW

ON

O

F

F

GND

DS1

L1

L2

L3

L1

R/

L2

S/

L3

T/

T1

U/

T2

V/

T3

W/

P1

P2

INPUT PO

WER

TERMINAL BLOCK

INSIDE VIEW

(DOOR NO

T SHO

WN FOR CLARITY)

TB

LR (OPTIONAL)

T

FU8

400

FRAME SIZE C

P

ANEL MOUNT

-RESTRICTED SP

A

CE-

MINIMUM MOUNTING

CLEARANCE ABO

VE

THE DRIVE IS 4.7"

-RESTRICTED SP

A

CE-

MINIMUM MOUNTING

CLEARANCE BELO

W

THE DRIVE IS 4.7"

DM1

PE GR

OUND

SIGNAL

TERMINAL BLOCK

OUTPUT PO

WER

TERMINAL BLOCK

FU3

FU2

FU1

Advertising