Figure 87, 97d00755, Cust omer terminals – Rockwell Automation 23C PowerFlex 400 AC Drive Packages for Fan & Pump Apps User Manual

Page 118

Advertising
background image

118

Rockwell Automation Publication 23C-IN001B-EN-P - June 2013

Chapter 2

3 Contactor Full Feature Bypass with Disconnect Package (Style B/N)

Figure 87 - 3.0…50 Hp, 208V AC & 3.0…100 Hp, 460V AC Drives with Line Reactor - NEMA/UL Type 1

97D00755

01

02

03

04

05

06

07

08

09

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

02

03

04

05

06

07

08

09

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

01

DA

T

E

REV

.

BY

ECN/CR.

NO

.

A

11/24/04

JRF

B

5/10/05

JRF

C

11/1/07

A

WR

D

6/25/08

A

WR

E

2/2/11

DJK

APPR

O

V

AL

DESIGN REVIEW

FOR MANUF

A

CTURING

AS SHIPPED

AS COMMISSIONED

BY

DA

T

E

SH.

NEXT

NO

.

SH.

-

DW

G

.

ENG.

TITLE

CHK.

BY

NO

.

DA

T

E

DA

T

E

DR.

BY

DA

T

E

THIS DRA

WING IS

THE PR

OPER

TY OF R

OCKWELL A

UT

OMA

TION, INC

.

OR ITS SUBSIDIARIES AND MA

Y NO

T BE COPIED

, USED OR DISCLOSED FOR ANY

PURPOSE EXCEPT AS A

UTHORIZED IN

WRITING BY R

OCKWELL A

UT

OMA

TION, INC

.

1

1

INTER-CONNECT DRA

WING - PF400, STYLE B

W/LINE REA

CT

OR

3-50HP @ 208V

A

C & 3-100HP @ 460V

A

C

97D00755

JRF/A

CI

5/17/04

JFH/A

CI

5/17/04

L3

INCOMING

3

f

PO

WER

L2

L1

CONNECTIONS SUPPLIED BY CUST

OMER

WILL REQ

UIRE MANU

AL RESET

.

OPENING OF

THE FREEZE/FIRE INTERLOCK

1

MAIN

DISCONNECT

SWITCH

T2

T1

T3

MG

32

31

33

34

35

36

37

38

39

CUST

OMER TERMINALS

BC

BYP

ASS

RU

N

PURGE

40

AUT

O ST AR

T

BYP ASS

STA

TU

S

INTERLOCKS

FREEZW/FIRE

T1

T2

T3

MO

T

OR

R/L1

T/L3

S/L2

P2

P1

U/T1

PO

WERFLEX 400

W/T3

V/T2

SPEED REF

. INPUT

0

T

O +10VDC

, 100K

OHM

INPUT IMPED

ANCE

2

+

SPEED REF

. INPUT

4-20MA, 250 OHM

INPUT IMPED

ANCE

+

2

PO38 [SPEED REFERENCE] =3 "ANALOG In2".

WIRE

T

O ANALOG INPUT #2 AND CHANGE P

ARAMETER

INPUT #1.

IF 4-20mA SOURCE IS

T

O BE USED

,

COME FR

OM 0-10V SOURCE

WIRED

T

O ANALOG

WHEN IN "A

UT

O MODE" SPEED REFERENCE

WILL

2

10V 20MA

RUN/FWD

FUNCTION LOSS

SOFTWARE ENABLE

DIGIT AL INPUT 1 (PURGE)

DIGIT AL COMMON

DIGIT AL INPUT 2 (LOCAL)

DIGIT AL INPUT 3 (CLEAR F

AUL

T)

DIGIT AL COMMON

DIGIT AL INPUT 4 (COMM POR

T)

1

3

24

7

5

6

89

10V 20MA

CONTR

OL BO

ARD

AO

2

10V 20MA

AO

1

AI1

ANALOG COM. #1

ANALOG OUTPUT #2 (OUTPUT CURRENT 0-10V)

ANALOG OUTPUT #1 (FREQUENCY 0-10V)

ANALOG INPUT #1

+ 10VDC

+ 24VDC

ANALOG INPUT #2

#1 RELA Y N.O

. (READ

Y/FA

UL T)

ANALOG COM #2

OPTO OUTPUT (A

T FREQUENCY)

#1 RELA Y COMMON

#1 RELA Y N.C

.

#2 RELA Y N.O

. (MO

TOR R

UNNING)

#2 RELA Y COMMON

#2 RELA Y N.C

.

RJ-45 SHIELD

OPTO COMMON

15

11

10

12

13

14

16

17

19

18

20

R3

R1

R2

R4

R5

R6

SRC

10V 20MA

AI2

SNK

DM1

DS1

G