Chapter 2
3 Contactor Full Feature Bypass with Disconnect Package (Style B/N)
Table 6 - Overload Ratings
Drive Rating
Overload Rating
Input Voltage
kW
Hp
Trip Class
Adjustment Rating (Amps)
208V AC – 3-Phase
2.2
3.0
20
3.2 - 16
3.7
5.0
20
5.4 - 27
5.5
7.5
20
9 - 45
7.5
10
20
9 - 45
11
15
20
18 - 90
15
20
20
18 - 90
18.5
25
20
18 - 90
22
30
20
40 - 200
30
40
20
40 - 200
37
50
20
40 - 200
460V AC – 3-Phase
2.2
3.0
20
3.2 - 16
4.0
5.0
20
3.2 - 16
5.5
7.5
20
3.2 - 16
7.5
10
20
5.4 - 27
11
15
20
9 - 45
15
20
20
9 - 45
18.5
25
20
9 - 45
22
30
20
9 - 45
30
40
20
18 - 90
37
50
20
18 - 90
45
60
20
18 - 90
55
75
20
40 - 200
75
100
20
40 - 200
90
125
20
40 - 200
110
150
20
40 - 200
132
200
20
100 - 500
160
250
20
100 - 500
200
300
20
100 - 500
250
350
20
100 - 500
Advertising