Table 22 - Auxillary Contacts (Fault & Aux #1)
Mechanical
Table 23 - Mechanical
Environmental
Table 24 - Environmental
UL/cUL/CSA
IEC
Rated Operational Voltage 250V AC/30V DC
250V~ / 30V DC
Rated Insulation Voltage 250V
250V~
Di-electric Withstand —
4 kV
Rated Impulse Voltage 1500 V AC
2000V-
Operating Frequency
50/60 Hz
Utilization Category D300
AC-15/DC
Control Circuit Type
Electro-magnetic Relay
Number of Contacts
1
Contact Type
Normally Open (N.O.)
Current Type
AC/DC
Rated Operational Current (max)
0.6 A @ 120 V~ and 0.3 A @ 240V~
Conventional Thermal Current (lth)
1 A
Make/Break VA
432/72
Resistance to Vibration Operational
1.0 G Peak, 0.15 mm (0.006 in) displacment
Non-Operational 2.5 G Peak, 0.38 mm (0.015 in) displacment
Resistance to Shock Operational
15 G
Non-Operational 5.5 G
Operating Temperature 0…50 °C (32…122 °F) Open
0…40 °C (32…104 °F) Enclosed
Altitude 2000 m (6560 ft)
Humidity 5…95% (non-condensing)
Pollution Degree 2