Protection dimensions [mm (in.)] mode of operation, Mounting information, Misalignment curve – Rockwell Automation 440N-Z21U16A_Z21U16B_Z21U16H_Z21U16J_Z21U26A_Z21U26B_Z21U26H_Z21U26J SensaGuard™ 18 mm Plastic Barrel Unique Coding Installation Instructions User Manual

Page 2: Status indicators, Nut torque specification, Minimum distance between sensors, 18 mm unit with 18 mm target, 2sensaguard™ 18 mm plastic barrel unique coding

Advertising
background image

Rockwell Automation 440N-IN013A-EN-P—October 2014

2

SensaGuard™ 18 mm Plastic Barrel Unique Coding

Protection

Dimensions [mm (in.)]

Mode of Operation

Status indicators:

“Power/Fault” LED illuminates green: Door/guard closed,

safety outputs active.

“Power/Fault” LED illuminates red: Door/guard open,

safety outputs off.

“Power/Fault” LED flashes red: Unit failure. See Diagnostic

section on page 3.

“Power/Fault” LED flashes green: Safety inputs off.

Short-circuit Incorporated

Current Limitation

Incorporated

Overload

Incorporated

False Pulse

Incorporated

Transient Noise

Incorporated

Reverse Polarity

Incorporated

Overvoltage

Incorporated

Thermal Shutdown/Restart

Incorporated

Electrical Life

10 x 10

6

30 mm Actuator

48.92

[1.926]

19.81
[0.78]

22.22

[0.875]

48.92

[1.926]

19.81
[0.78]

22.22

[0.875]

30.40

[1.197]

16.84

[0.663]

3.17

[0.125]

4.57

[0.18]

2 places

Dia.

Sensor

18 mm Actuator

67.06

[2.640]

2.03

[.080]

M18X1

36.47

[1.436]

13.72
[0.54]

15.87

[0.625]

36.47

[1.436]

13.72
[0.54]

15.87

[0.625]

4.57

[0.180]

DIA

19.81
[0.78]

3.17

[0.125]

15.42

[0.607]

2 PLACES

Mounting Information

Use non-removable screws, bolts, or nuts to mount the switch and
actuator. Do not over torque the mounting hardware.

Position the switch and actuator so they are aligned with each
other.

Mount the switch and actuator to removable guard, door, or gate.
Keep the switch and actuator within the sensing range below.

This switch is not meant to be fully embedded in metal. Use the
stainless steel version (440N-Z21S17* or 440N-Z21U17*) for
embedding.

Nut Torque Specification

Plastic Barrel Switch: 2.26 N•m (20 in•lb)
Plastic Actuators: 2.26 N•m (20 in•lb)

Minimum Distance Between Sensors

Misalignment Curve

18 mm Unit with 18 mm Target

There must be a minimum spacing of 4 mm
(0.157 in.) if actuator and sensor face approaches
laterally. This will prevent false triggering due to
the side lobe areas.

18 mm Actuator

75 mm

Sensor

1

Sensor

2

30 mm Actuator

100 mm

Sensor

1

Sensor

2

Lateral Misalignment Tolerance—mm (in)

Face to Face Distance—mm

-15

(-0.59)

-10

(-0.39)

-5

(-0.19)

0

5

(0.19)

10

(0.39)

15

(0.59)

0

5

10

15

20

25

-25

(-0.98)

-20

(-0.787)

20

(0.787)

25

(0.98)

Side Lobe

Side Lobe

Assured Sensing

Distance

OFF

OFF

ON

Assured Sensing

Distance

OFF

IMPORTANT

Advertising