Troubleshooting, Sensaguard™ 18 mm plastic barrel unique coding 5 – Rockwell Automation 440N-Z21U16A_Z21U16B_Z21U16H_Z21U16J_Z21U26A_Z21U26B_Z21U26H_Z21U26J SensaGuard™ 18 mm Plastic Barrel Unique Coding Installation Instructions User Manual

Page 5

Advertising
background image

Rockwell Automation 440N-IN013A-EN-P—October 2014

SensaGuard™ 18 mm Plastic Barrel Unique Coding

5

Troubleshooting

Series Circuit

Unit Response Time (does not include safety control system response time)

Refer to Technical Specifications (page 1) for
certification information and ratings.

Refer to Technical Specifications (page 1) for
certification information and ratings.

Ye
l

Red

Br
own

Gray

Pink

Blue

24VDC

Power

Supply

1606

-XL120D

Switch 1

+24

RTN

Switch 2

White

White

Ye
l

Red

Br
own

Gray

Pink

Blue

Actuator 1

Actuator 2

Switch 3

White

Ye
l

Red

Br
own

Gray

Pink

Blue

Actuator 3

Switch 4

White

Ye
l

Red

Br
own

Gray

Pink

Blue

Actuator 4

Switch 5

White

Ye
l

Red

Br
own

Gray

Pink

Blue

Actuator 5


+24 V

+24 V

+24 V

+24 V

+0 V

+0 V

+0 V

+0 V

+0 V
+0 V

Actuator 2 is in sensing range.
Switch
2 is functioning properly
OSSDs are energize to 24 V
Green LED is ON.

Actuator 3 is in sensing range.
Switch
3 has fault.
See Table Above—Red LED is flashing

Actuator 1 is in sensing range.
Switch
1 is functioning properly
OSSDs are energize to 24 V
Green LED is ON.

Actuator 4 is in sensing range.
Switch
4 is functioning properly

.

Series inputs are 0 V .
OSSDs are de-energized to 0V .
Green LED is Flashing to indicate
Series inputs are not 24 V.

Actuator 5 is in sensing range.
Switch
5 is functioning properl y .
Series inputs are 0 V .
OSSDs are de-energized to 0V.
Green LED is Flashing to indicate
Series inputs are not 24 V.

OSSD ’s are OFF

Recoverable fault

IMPORTANT

Yel

Red

White

Gray

Pink

Blue

24V DC

Power

Supply

1606

Sensor 1

+24

RT

Sensor 2

Brown

Brown

Gray

Pink

White

Yel

Red

Blue

Sensor 3

Brown

Yel

Red

White

Gray

Pink

Blue

A1

S21

S11

41

33

23

13

S12

S52

42

34

24

14

A2

S34

S22

MSR127TP

Actuator 1

Actuator 2

Actuator 3

Initial Conditions:
All actuators are in sensing
distance.

Actuator 1 is moved out of
sensing range.

Sensor 2 drops the 24 volts
(red and yellow) from Sensor 1
OSSD outputs.
Green LED flashes.

Sensor 3 drops the 24 volts
(red and yellow) from Sensor 2
OSSD outputs.
Green LED flashes.

0 ms

54 ms

72 ms

90 ms

Actuator 1 is out of sensing
range.
Actuator 2 and 3 are in
sensing range.

Actuator 1 is moved into sensing
range.
Sensor 1 OSSD outputs are
energized.

Sensor 2 OSSD inputs (red and yellow)
transition to 24V DC from Sensor 1
OSSD outputs.
Sensor 2 OSSD outputs are energized

Sensor 3 OSSD inputs (red and
yellow) transition to 24V DC from
Sensor 2 OSSD outputs.
Sensor 3 OSSD outputs are
energized.

0 ms

360 ms

378 ms

396 ms

OFF

ON

IMPORTANT

Advertising