Connection information, Connection table, Wiring diagram – Rockwell Automation 440N SensaGuard Magnetically Coded NonContact Switch (MC2) User Manual
Page 7: Recommended mating cable

7. Connection Information
7.3
Connection Table
MSR100 family
MSR200/300
Red/Safety A
S11
S11
Grey/Safety A
S12
S12 or S42
Yellow/Safety B
S21
S21
Pink/Safety B
S22
S22 or S52
Brown / +24V
A1 / +24V
A1 / +24V
Blue / 0V
A2 / 0V
A2 / 0V
Note: When the MC2 is used with any MSR100 series Relay for the diagnostic function to operate
correctly the Red and Grey wires (Safety A) must be connected to S11 and S12.
72697 Issue 4 EO: 28485
Magnetically Coded Non Contact Switch Installation Instructions 7
Note: Refer to Technical Specifications for Certification information and ratings.
7.1
Wiring Diagram
Pin #
Wire Colour
Signal
1
White
PNP Aux
2
Brown
+24V
3
Green
Not connected
4
Yellow
Safety B
5
Grey
Safety A
6
Pink
Safety B
7
Blue
0V
8
Red
Safety A
7.2
Recommended Mating Cable
For 8-Pin micro (M12) option. 889D-F8AB-*. Lengths are available up to 30m (98.4 ft)
+24V
Aux
Gnd
Safety B
Safety A
Not
connected
Safety A
Safety B
4
7
6
8
1
5
2
3