Application wiring examples – Rockwell Automation 440N SensaGuard Magnetically Coded NonContact Switch (MC2) User Manual

Page 9

Advertising
background image

10. Application Wiring Examples

10.1

Single Switch, Automatic Reset, Monitored Outputs MSR127TP

72697 Issue 4 EO: 28485

Magnetically Coded Non Contact Switch Installation Instructions 9

Note: Refer to Technical Specifications for Certification information and ratings.

+24v

0v

Safety A+

Safety A-

Safety B+

Safety B-

Aux

Not

33

13

A1

S11

S12

23

S34

14

A2

S21

S22

24

MSR127R

P

+24V

0V

S52

4

1

34

42

K1

K2

L1

L2

L3

Brown (2)

Blue (7)

Red (8)

Grey (5)

Yellow (4)

Pink (6)

Green (3)

White (1)

MC2

Red

Grey

Pink

Yellow

Note: To maintain correct

diagnostic operation the

red w

ire (QD pin 8) must

be connected to S11.

Connected

Advertising