5

ArmorConnect Power Media

Description

The ArmorStart Power Media offers both three-phase and control power
cable system of cordsets, patchcords, receptacles, tees, reducers and
accessories to be utilized with the ArmorStart Distributed Motor Controller.
These cable system components allow quick connection of ArmorStart
Distributed Motor Controllers and reduce installation time. They provide
for repeatable, reliable connection of the three-phase and control power to
the ArmorStart Distributed Motor Controller and motor by providing a plug
and play environment that also avoids system mis-wiring. When specifying
power media for use with the ArmorStart Distributed Motor Controllers
(Bulletins 280G/281G and 284G) use only Bulletin 280 ArmorConnect™
power media.

Figure 4 Three-Phase Power System Overview

➊ Three-Phase Power Trunk- PatchCord cable with integral female or male connector on each end. (Example Part Number: 280-PWR35A-M*)
➋ Three-Phase Drop Cable- PatchCord cable with integral female or male connector on each end. (Example Part Number: 280-PWR35A-M*)
➌ Three-Phase Power -

Tee connects to a single drop line to trunk with quick change connectors – Part Number: 280-T35

➍ Three-Phase Power Receptacles -

Female receptacles are a panel mount connector with flying leads – Part Number: 280-M35F-M1