Technical Data

28

7

Technical Data

7. 1

Display Version

7.1.1

Power Supply

Supply voltage
•

DC voltage version
12...30V DC

Current consumption
•

Without load < 60 mA, with reverse polarity protection

Power supply failure
•

Behavior in case of over voltage
The device works continuously without any damage up to 34V DC.
If the supply voltage is exceeded, the properties specified are no longer guaranteed.

•

Behavior in case of under voltage
If the supply voltage drops below the minimum value, the device switches off (status as if
not supplied with power = switch open).

7.1.2

Output

Switching capacity
•

Switch status ON: I

a

≤ 250 mA

•

Switch status OFF: I

a

≤ 1 mA

•

Switching cycles: > 10 000 000

•

Voltage drop PNP: ≤ 2V

•

Overload protection
Automatic load check of switching current; output is switched off in case of over current,
the switching current is tested again every 0.4 sec.; max. capacitance load: 14 μF at max.
supply voltage (without resistive load) max. period length: 0.5 sec.; min. t

on

: 40 μs

Load (analog output)
•

Max. (V

supply

− 6.5V)/0.022 A

Input PLC
•

Input resistance R

i

≤ 2 kΩ

Input current I

i

≥ 10 mA

Signal on alarm
•

Analog output

≤ 3.6 mA / last current value / ≥ 21.0 mA adjustable
(if setting ≥ 21.0 mA the output is ≥ 21.5 mA)

•

Signal outputs
In safe state (switch normally open)

Advertising