Technical data 29, 2 nondisplay version – Rockwell Automation 836E Solid-State Pressure Sensors User Manual
Page 29

Technical Data
29
7.1.3
Operating Conditions
Any orientation
Any position-dependent zero shift can be corrected
Position adjustment (offset): ±20% of the upper range limit
Operating conditions: Environment
•
Ambient temperature range
–40...+85 °C (briefly up to +100 °C [212 °F]), (–40...+185 °F)
•
Storage temperature
–40...+85 °C (–40...+185 °F)
Operating conditions: Process
•
Medium temperature ranges
−40...+100 °C (–40...+212 °F)
Limiting medium pressure range
•
For overload resistance, see nameplate (Section 2)
•
Vacuum resistance: 10 mbar
abs
Material: AISI 316L
7. 2
Nondisplay Version
7.2.1
Power Supply
Supply voltage
•
DC voltage version
12...30V DC
Current consumption
•
20 mA
7.2.2
Output
Output signal
•
4…20 mA
Maximum load
•
Max. (V
supply
− 12V)/0.02 A
7.2.3
Operating Conditions
Ambient temperature range
•
–25…+70 °C (–13…+158 °F)
Medium temperature range
•
–25…+70 °C (–13…+158 °F)
Storage temperature range
•
–40…+85 °C (–40…+185 °F)